期刊文献+

自适应浮阀塔板HAV^(TH)的操作特性 被引量:4

STUDY ON THE OPERATION PERFORMANCE OF SELF-ADAPTING VALVE TRAYS
下载PDF
导出
摘要 为了提高蒸馏塔板的分离性能,在综合了国内外新型固阀和浮阀塔板优良性能的基础上开发了一种固阀与浮阀相集成的高效自适应塔板(HAVTH)。采用空气水氧气体系,在直径为600mm的塔内,研究了HAVTH塔板的流体力学和传质性能,并与F1浮阀塔板进行了对比试验。结果表明:HAVTH塔板与F1浮阀塔板相比,具有操作弹性大、压降低、雾沫夹带和泄漏小、传质效率高等优点。 A new high efficient self-adapting valve tray (HAV TH),integrated the high performance of fixed trays and valve trays,was developed. The hydrodynamics and mass transfer performance of the HAV TH trays and F1 valve trays were studied with an air-water-oxygen system by using a Φ600 mm stainless steel column. The experimental results showed that as compared with F1 valve trays,the HAV TH trays offered better operation flexibility,lower pressure drop,higher mass transfer efficiency,less entrainment and loss.
机构地区 清华大学化工系
出处 《石油炼制与化工》 CAS CSCD 北大核心 2005年第4期61-64,共4页 Petroleum Processing and Petrochemicals
关键词 蒸馏塔板 分离性能 空气-水-氧气体系 传质效率 塔板压降 雾沫夹带 塔板泄漏 valve tray fluid flow distillation column mass transfer efficiency
  • 相关文献

参考文献6

二级参考文献15

  • 1王忠诚,曾爱武,吴剑华,张雅芝,黄洁.新型塔板──导向梯形浮阀塔板的流体力学性能[J].石油炼制与化工,1995,26(11):36-40. 被引量:21
  • 2路秀林,实用新型专利91215110.2,1991年
  • 3匿名著者,化学工程手册.3,1989年
  • 4路秀林,化学世界,1987年,1期,27页
  • 5路秀林,华东化工学院学报,1983年,4期,535页
  • 6黄洁,化工学报,1994年,45卷,3期,J306页
  • 7路秀林,化工装备技术,1992年,13卷,1期
  • 8团体著者,化学工程,1978年,4卷,74页
  • 9团体著者,石油化工,1977年,6卷,5期,478页
  • 10团体著者,石油炼制,1992年,5卷,1期

共引文献33

同被引文献91

引证文献4

二级引证文献19

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部