期刊文献+

税控燃油加油机电气配线经验交流 被引量:1

Experience on the Electrical Wiring of the Oil-Fulling Dispenser with Tax Control
下载PDF
导出
摘要 作为复合型的防爆电气设备,税控燃油加油机的电气配线及接地等由于某些影响因素的长期作用,会形成不安全爆炸隐患。文章介绍了税控型燃油加油机电气配线的安全防爆要求,讨论了加油机在选型、维护和电气设备接地等方面应注意的问题。 As a combining protection type Ex-equipment, it will causes some potential explosive hazards in the electric wiring and earthing of the fuel-filling dispenser with tax control, impacted by some infuencing factors during long term operation. This article presents the requirements on explosion protection technology for the elelctrical woring of the dispenser, draws attention to the selection, service, maintenance and earthing for the dispenser.
机构地区 南阳理工学院
出处 《电气防爆》 2005年第2期32-34,共3页 Electric Explosion Protection
关键词 加油机 电气配线 防爆要求 dispenser electrical wiring explosion protection requirement