摘要
针对国内中压电网的结构和特性进行了分析,给出了国内中压线路的宽带电力线通信(PLC)接入方式及其接入原理,对中压线路的接入设备、接入接口进行了归纳,在此基础上完成了国内第1条实际的中压PLC信道的测试,给出了反映信道特性的测试结果并进行了分析与研究。所完成的中压PLC信号的传输实验和测试研究,为宽带PLC进一步向中压电力线发展提供了设计依据和技术储备,为未来中压线路全程长距离接入提供了参考数据和资料。
According to the structure and characteristics of medium-voltage networks in operation in China, the access mode and principles of broadband power line communication (PLC) on medium-voltage lines are discussed. Based on the generalization of the access equipment and the access interface, the test on the first medium-voltage PLC channel in China is completed and the result of channel test is analyzed and studied. The transmission experiment and test study on medium-voltage power lines have provided the design basis and technology support for further development of broadband PLC on the medium-voltage power lines and reference data for the future long distance access of medium-voltage lines.
出处
《电力系统自动化》
EI
CSCD
北大核心
2005年第14期69-72,共4页
Automation of Electric Power Systems
基金
国家自然科学基金资助项目(60372035)
关键词
中压电力线通信
接入方式
信道特性测试
Broadband networks
Communication channels (information theory)
Electric lines