期刊文献+

弹力内锁钉与交锁钉固定股骨中下段骨折的生物力学比较 被引量:1

Biomechanical study of elastic interlocking intramedullary nail and interlocking nail for the fixation of distal femoral fracture
下载PDF
导出
摘要 目的:比较弹力内锁髓内钉与交锁钉固定股骨中下段骨折的生物力学性能。方法:用8根新鲜成人股骨标本,制成股骨中下2/5骨折模型,分别用弹力内锁髓内钉、国产交锁髓内钉、梅花钉和钢板内固定,对内固定后的标本进抗扭转测试,用spss统计软件对实验数据进行分析。结果:弹力内锁钉在5Nm扭矩下抗旋转刚度接近交锁髓内钉。结论:弹力内锁钉在冶疗股骨中下段骨折中固定可靠,符合生物力学要求。该器械结构合理,简单实用,有一定的临床价值。 Objective: To compare the biomechanical properties of elastic interlocking intramedullary nails and interlocking intramedullary nails for the fixation of distal femoral fracture. Methods: 8 fresh femurs were obtained from adult cadavers to produce fracture models of the femur shaft at the lower 2/5 part. Elastic interlocking intramedullary nails, the interlocking nails, Meihua nails and steel plates were adopted and the anti-torsion was tested. The biomechanical parameters of the fixations were measured and the results processed with SPSS software. Results: Elastic interlocking intramedullar nails and interlocking nails possessed the similar rigidity against rotation under 5Nm torque. Conclusions: Elastic interlocking intramedullar nail possess good biomechanic property and can produce firm fixation for femoral fracture, thus being of value in the fracture clinic practice. The instrument structure was reasonable, simple and practical.
出处 《中国临床解剖学杂志》 CSCD 北大核心 2005年第4期431-433,共3页 Chinese Journal of Clinical Anatomy
基金 广东省科技攻关项目(99B06703G)
关键词 股骨骨折 骨折固定 弹力内锁髓内钉 交锁钉 生物力学 ] femoral fracture fracture fixation elastic interlocking intramedullary nails interlocking intramedullary nails biomechanics
  • 相关文献

参考文献7

二级参考文献17

共引文献83

同被引文献11

  • 1杨云平,杨轲颖,王宇飞,陆晓涛,李光全.带锁髓内钉临床应用的并发症及预防[J].临床骨科杂志,2005,8(3):235-237. 被引量:29
  • 2叶毓麟,钱成雄,吴坤南.髓腔延长顺行交锁髓内钉治疗股骨远端骨折基础与应用研究[J].中国临床解剖学杂志,2005,23(4):440-442. 被引量:4
  • 3李颖,吴继明,杨光新,马保安,范清宇.股骨自锁髓内钉的设计与生物力学特性[J].中华创伤骨科杂志,2005,7(10):935-938. 被引量:6
  • 4姜升平,符小舢,蒲云清.梅花针加记忆合金接骨板内固定治疗股骨干粉碎性骨折[J].生物骨科材料与临床研究,2005,2(5):54-54. 被引量:1
  • 5Schandelmaier P, Farouk O, Krettek C, et al. Tscherne Biomechamics of femoral interlocking femoral nails. Injury, 2000, 31 (6):437-443.
  • 6Schandelmaier P, Farouk O, Krettek C, et al. Biomechanics of femoral interlocking nails[J]. Injury, 2000, 31 (6):437-443.
  • 7Barei DP, Taitsman LA, Beingessner D, et al. Open diaphyseal long bone fractures: a reduction method using devitalized or extruded osseous fragments[J]. J Orthop Trauma, 2007, 21(8): 574-578.
  • 8Bielecki T, Gazdzik TS, Jurkiewicz A. Possibilities of surgical treatment of bone metastases to the proximal epiphysis of the femur: a review of the literature and own experience[J]. Orthop Traumatol Rehabil, 2003, 5 (3):305-312.
  • 9Heiney JP, Barnett MD, Vrabec GA, et al. Distal femoral fixation: a biomechanical comparison of trigen retrograde intramedullary nail, dynamic condylar screw (DCS), and locking compression plate (LCP) condylar plate[J]. J Trauma, 2009,66(2):443-449.
  • 10Chen SH, Yua TC, Chang CH, et al. Biomechanical analysis of retrograde intramedullary nail fixation in distal femoral fractures [J]. Knee, 2008, 15(5):384-389.

引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部