摘要
压力试验机的上压板采用不同的安装方式,对相同的包装容器进行压力试验,通过对试验结果的系统误差分析和随机误差分析,认为对强度均匀的包装容器的压力试验,上压板的两种安装方式对试验结果无影响。
The pressure tests of the the same packaging container were come off by applying the different installed mathods of the clamp plate in the pressure test machine.The result of the test didn't charge even if two different installed methods of the clamp plates in pressure test of the regular strength packaging container,according to systematic and rendom error analysis of the result of the test.