本文探讨了快速有功补偿器对电力系统阻尼的影响,并和快速无功补偿器的阻尼作用进行了比较。研究表明,这种FACTS装置为抑制系统低频振荡提供了强有力的手段。
In this paper, the influence of highspeed active compensator,a FACTS equipment,onpower system damping is expounded , and the dampingeffect of high speed reactive cornpensator and that ofthe active compensator is compared. The results ofcalculation andsimulation indicate that the FACTS e-quipment can provide an effective means to suppressthe low frequency oscillation in power system.