期刊文献+

酪氨酸酶电流传感器测定低浓度氰化物抑制剂的研究 被引量:6

Tyrosinase Amperometric Biosensor for Monitoring Inhibitor of Low Concentration of Cyanide
下载PDF
导出
摘要 用预活化聚酰胺膜固定酪氨酸酶,制得性能良好的酪氨酸酶生物传感器,以此测定CN~-抑制剂的含量。在磷酸盐缓冲溶液中,以苯酚作底物,浓度范围为5×10^(-6)~4×10^(-5)mol/L,当苯酚浓度一定时,还原电流(-0.200V,vs,SCE)的下降值与CN~-浓度的平方根成线性关系,检测范围为5×10^(-7)~2×10^(-4)mol/L,有良好的选择性和重现性。 Cyandide inhibitor of tyrosinase was determied with biosensor of tyrosinase by using tyrosinase immobilized on a preactivated polyaminde membrane.Phenol with the range of concentration 5×10 ̄(-6)~4×10 ̄(-5) mol/L was chosen as substrate in phosphate buffer.The de-crease of substrate response have linear relation with square root of concentration of CN ̄-with detection range of 5 ×10 ̄(-7)~2×10 ̄(-4) mol/L. The fine selectivity and reproducibility were obtained.
出处 《高等学校化学学报》 SCIE EI CAS CSCD 北大核心 1995年第3期359-362,共4页 Chemical Journal of Chinese Universities
基金 江苏省教育委员会自然科学基金
关键词 生物传感器 酪氨酸 氰化物 抑制剂 Electrode,Biosensor,Enzyme,Tyrosinase,Cyanide
  • 相关文献

参考文献2

  • 1胡乃钊,毒物分析化学,1986年
  • 2曾北危,环境分析化学,1979年

同被引文献84

引证文献6

二级引证文献149

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部