期刊文献+

采用V型极板收集高比电阻粉尘的实验研究 被引量:6

Experimental Study on the Collection of High Specific Resistivity Dusts by V-shaped Collecting Electrodes
下载PDF
导出
摘要 改变电除尘器的收生极板形状,采用顶角45°-90°的V型收尘极板横向放置。结果表明,可有效地将荷电粉尘粒子和空间自由离子分开,减小粉尘层电流密度,可收集比电阻力1011—1013Ω·cm的高比电阻粉尘,通过模拟实验研究,给出了清洁极板,附不同比电阻。以及V型极板的顶角在45°-90°间发生变化时极板的电流密度分布。 he use of 45 to 90 degree angled V--shaped collecting electrodes in a transverse arrangement tochange the configuration of collecting electrodesin an electrostatic precipitator was found to effectively separate free ions in space from chargeddust particles and to reduce the current density ondust layes So that the high specific resistivitydusts with a resistivity of 1011to 1013 Ω. cmcould be collected. By carrying out simulated experimental study, the distribution of current density on electrodes was given for clean electrodescovered with dielectric materials of different resistivities, which were V--shaped at an angle changing between 45 and 90 degree.
作者 李杰 刘林茂
出处 《环境科学》 CAS CSSCI CSCD 北大核心 1995年第6期33-35,共3页 Environmental Science
关键词 静电除尘 高比电阻 电除尘器 粉尘 V型极板 electrostatic precipitator, highspecific resistivity dust, current density.
  • 相关文献

参考文献3

  • 1刘林茂,北京国际静电会议论文集,1988年
  • 2王锡录,东北师大学报,1988年,1期,27页
  • 3王成汉,工业电收尘,1984年

同被引文献30

  • 1赵会良,吴维韩,罗承沐,郭小明,王幽林.反电晕及其抑制措施[J].高电压技术,1995,21(2):20-23. 被引量:12
  • 2陈旺生,邹霖,党太升,向晓东,黄三明,李华,陶红森.泛比电阻电除尘器伏安特性的理论及实验研究[J].环境科学与技术,2005,28(6):25-27. 被引量:5
  • 3原永涛,齐立强.燃煤飞灰伏安特性的实验研究[J].热能动力工程,2006,21(1):58-61. 被引量:6
  • 4陈旺生,向晓东,陆继东.电除尘器粉尘层反电晕击穿厚度理论与试验[J].环境科学与技术,2006,29(10):32-33. 被引量:9
  • 5韩学洲.引进粉末喷涂设备的体会[J].通讯电源技术,1994,(3):7-9.
  • 6Blanchard D. , Atten P. Correlation between current desity and layer structure for fine particles deposition in a laboratory electrostatic precipitator. IEEE Transactions Industry Application ,2002,38 ( 3 ) :838-834.
  • 7Prasad N. V. P. R. D., Lakshminarayana T. Automatic control and management of electrostatic precipitator. IEEE Trans. on Industry Applications, 1999,35 ( 3 ) :561-567.
  • 8向晓东.原式静电除尘器应用评价[J].环境工程,1987,(5):19-24.
  • 9Chung-Liang Chang, Hsunling Bai. An Experimental Study on the Performance of a Single Discharge Wire-plate Electrostatic Precipitator with Back Corona[J]. J. Aerosol Sei,1999, 30(3): 325-340.
  • 10张国权 向晓东.线板—板型静电除尘器收尘性能的研究[J].工业安全与防尘,1986,(8):6-11.

引证文献6