摘要
本文用能流图对中高档旅馆冬、夏和过渡季各种废热排放量作了定量分析,还对废热利用的必要条件及其季节性,中高档旅馆对“热”的季节需求量,热泵技术在利用这些应热中的适用性与几种可行的工程技术方案进行了较详细的讨论与分析。最后,就中高档旅馆的废热利用提出了六.点原则性意见。
This paper, using energy flow charts, makes a quantitative analysis of various wast heat exhaust throughout the four seasons of the year in middle and high standard hotels. It then discusSes in more detail the essential conditions of the wast heat use, the seasonal requirement for the 'heat' and applicability of heat pump technology in using these wast heats and finally makes six recommendations for recovering the wast heat.
出处
《暖通空调》
北大核心
1995年第4期23-29,共7页
Heating Ventilating & Air Conditioning
关键词
旅馆
废热利用
排放
定量分析
能流图
waste heat recovery, middle and high standard hotel, energy flow chart, quantitative analysis