摘要
建立了红外光谱法测定无铅汽油中MTBE的方法。运用可调厚度吸收池消除汽油背景所产生的影响。当LITBE含量为1.5-12g/100ml时,其误差为0.6-2.9%,对含MTBE为4g/100ml的试样分析7次的相对标准偏差为2%。该方法快速、简单,可用于汽油中MTBE的测定。
An infrared spectrophotometric method for determining MTBE in unleaded gasoline isestablished. The effect caused by gasoline background is removed by variable space cell. ForMTBE content of 1.5一12g/100ml,the error is 0.6-2.9%,and the recovery is 97-102%。The RSD for samples containing 4g/100ml of MTBE is 2%(n=7).The method is rapid,simple and can be applied to the determination of MTBE in gasoline.