期刊文献+

Flow injection spectrophotometric determination of vitamin E in pharmaceuticals,milk powder and blood serum using potassium ferricyanide-Fe(Ⅲ) detection system 被引量:3

Flow injection spectrophotometric determination of vitamin E in pharmaceuticals,milk powder and blood serum using potassium ferricyanide-Fe(Ⅲ) detection system
下载PDF
导出
摘要 A simple and sensitive flow injection spectrophotometric method is reported for the determination of vitamin E using potassium ferricyanide-Fe(Ⅲ) detection system.In the presence of vitamin E,Fe(Ⅲ)/ferricyanide reduces.The in situ reduced ions are then reacted with unreduced portion of ferricyanide/Fe(Ⅲ) to make soluble Prussian blue,which is monitored at absorption wavelength of 735 nm.Linear calibration graph was obtained in the concentration range of 0.1-40μg mL^(-1).The relative standard deviations (n=4) were in the range of 1.1-3.6%,with limits of detection(3 s blank) of 0.04μg mL^(-1).The proposed method allowed 12 injections h^(-1).The method is applied to determine vitamin E in pharmaceuticals,infant milk and blood serum samples using hexane extraction with the recoveries in the range of 93±3 to 97.5±4%.The method is validated using certified reference materials SRM 968c for blood serum samples. A simple and sensitive flow injection spectrophotometric method is reported for the determination of vitamin E using potassium ferricyanide-Fe(Ⅲ) detection system.In the presence of vitamin E,Fe(Ⅲ)/ferricyanide reduces.The in situ reduced ions are then reacted with unreduced portion of ferricyanide/Fe(Ⅲ) to make soluble Prussian blue,which is monitored at absorption wavelength of 735 nm.Linear calibration graph was obtained in the concentration range of 0.1-40μg mL^(-1).The relative standard deviations (n=4) were in the range of 1.1-3.6%,with limits of detection(3 s blank) of 0.04μg mL^(-1).The proposed method allowed 12 injections h^(-1).The method is applied to determine vitamin E in pharmaceuticals,infant milk and blood serum samples using hexane extraction with the recoveries in the range of 93±3 to 97.5±4%.The method is validated using certified reference materials SRM 968c for blood serum samples.
出处 《Chinese Chemical Letters》 SCIE CAS CSCD 2010年第6期712-715,共4页 中国化学快报(英文版)
关键词 Flow injection SPECTROPHOTOMETRY Vitamin E Prussian blue FE(III) FERRICYANIDE Pharmaceuticals Blood serum Flow injection Spectrophotometry Vitamin E Prussian blue Fe(III) Ferricyanide Pharmaceuticals Blood serum
  • 相关文献

参考文献2

二级参考文献10

  • 1H.Parham,B.Zargar. Talanta . 2005
  • 2.Inorganic Chemistry(PartⅢ)[]..2002
  • 3J.M.Pan,Y.S.Chen,H.T.Yan.Application of the Chromogenic Reagent in Metallurgical Analysis[]..1981
  • 4F.G.Cheng. J.South-Central Univ.Nation . 2006
  • 5.Inorganic Chemistry(PartⅢ)[]..2002
  • 6Hillert S.Vanden Bossche W[].Journal of Pharmaceutical and Biomedical Analysis.1999
  • 7Economou-Demetrius A.Themelis Gerogios G.Paraskevasel Tzanavaras T[].Analytica Chimica Acta.2002
  • 8Florentin Tache,Alexandru Farca,Andrei Medvedovici,et al.Validation of a LC-fluorescence method for determination of free captopril in human plasma, using a precolumn derivatization reaction with monobromobimane[].J Pharmaceut Biomed Anal.2002
  • 9A V Prior,L M Santos,L F C Lima.Exploiting kinetic spectrophotometric determination of captopril,an angiotensin-converting enzyme inhibitor in a multi-pumping flow system[].Analytica Chimica Acta.2007
  • 10MAZUREK S,SZOSTAK R.Quantitative determina-tion of captopril and prednisolone in tablets by FT-Ramanspectroscopy[].Journal of Pharmaceutical and Biomedi-cal Analysis.2006

共引文献3

同被引文献28

引证文献3

二级引证文献32

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部