针对孤东采油厂集输联合站管道腐蚀十分严重、穿孔比较频繁的现状,分析了腐蚀产生的原因,采取了加强管道防护保温、强制阴极保护法等措施,防止了联合站管道的腐蚀。
Aimed al the present conditions of severe corrosion of the pipeline of joint station of Gudong recovery plant,and the frequent perforation,the causation of the corrosion has been analyzed,the countermeasures of heat preservation of pipeline protection,and mandatory cathodic protection have been used,to prevend the pipeline of joint station from corrosion.