摘要 本文探讨了以分子筛组装Bi2O3代替标准重铬酸钾法中的Ag2SO4,用密封消解法测定废水COD值的可行性,研究了催化剂的用量、溶液的酸度、消解时间及温度等因素对COD测定的影响。通过对各种废水COD值的测定表明,用分子筛组装Bi2O3做催化剂,在165℃,较低酸度,密封消解15min是可行的,并能显著降低分析费用。 The molecular sieve -Bi2O3 is introduced as a catalyst instead of Ag2SO4 for standard determination of COD. Influence of dosage of catalyst, acidity of solution, digesting time and digesting temperature on determination of COD is discussed. The result indicate that the molecular sieve - Bi2 O3 catalyst is feasible in condition of 165℃ and relatively Iow acidity for 15 minute sealed digestion.
出处 《山东农业大学学报(自然科学版)》 CSCD 北大核心 2005年第3期363-366,共4页 Journal of Shandong Agricultural University:Natural Science Edition
关键词 COD 分子筛 BI2O3 催化剂 COD, molecular sieve, Bi2O3, catalyst
  • 相关文献

参考文献6

  • 1Selvapathy P,Jogabeth J Starlet.A new catalyst for determination[J].India J.Environ.Health.1991,33(1):96-102.
  • 2王军,范顺利,刘兴旺.用CuSO_4-KAl(SO_4)_2-Na_2MoO_4作催化剂快速测定COD[J].环境科学,1992,13(3):66-69. 被引量:30
  • 3Sun Jianhui,Xia Siqing,Sun Ruixia.Rapid determination of wastewater COD using Mn(H2PO4)2 as catalyst [J].Environ Sci,1996,8(2):212-217.
  • 4张松滨,李万海,王红.用MnSO_4作催化剂测定废水中的COD[J].化工环保,2001,21(3):171-173. 被引量:17
  • 5ISO6066-86(E).国际标准:水质:化学需氧量的测定.[S].,..
  • 6Czae Myung-Zoon,et al.Chemical oxygen based on spectrophotometric measurement of permangement[J].J.Korean Chem.Soc.,1994,38(2):880-884.

二级参考文献12

  • 1韦利杭.化学需氧量快速测定法的研究[J].环境污染与防治,1995,17(3):38-41. 被引量:38
  • 2尹淆.介绍处理COD的新技术[J].中国环境监测,1985,1(1):10-15.
  • 3张萃民,环境化学,1989年,8卷,2期,62页
  • 4团体著者,环境监测分析方法,1986年
  • 5尹洧,上海环境科学,1985年,4卷,7期,32页
  • 6黄叶丹,环境化学,1989年,3卷,5期,36页
  • 7张华民,环境化学,1989年,8卷,2期,64页
  • 8尹淆,中国环境监测,1985年,1卷,1期,10页
  • 9污染源统一监测分析方法编写组,污染源统一监测分析方法,1983年,45页
  • 10张莘民,高明慧.化学需氧量的分析[J].环境化学,1989,8(2):62-69. 被引量:15

共引文献42

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部