可用传输容量(ATC)计算已成为电力市场研究的一个重要部分。将一种信赖域内点法应用到基于最优潮流(OPF)的总传输容量(TTC)计算模型中,以IEEE-39节点系统为例进行了验证计算,并就此算法的优化性能与连续二次规划法(SQP)进行了比较。
ATC computing becomes an important issue in the research of electrical power market. This paper applies a trust region interior-point algorithm to TTC calculation model based on OPF method. IEEE 39 bus system is used for testing the proposed algorithm and the result is compared with that from the SQP algorithm.
出处
《电力系统及其自动化学报》
CSCD
北大核心
2005年第5期71-74,共4页
Proceedings of the CSU-EPSA
关键词
信赖域内点法
总传输容量
可用传输容量
最优潮流
连续二次规划法
trust region interior-point algorithm
total transfer capability(TTC)
available transfer capability (ATC)
optimal power flow(OPF)
sequential quadratic programming(SQP)