摘要
为了对310 t/h循环流化床石油焦混烧锅炉运行特性有较全面的了解,通过实验研究了不同焦煤混合比、不同配风方案以及不同负荷下的锅炉运行情况和经济性指标,探索了这些因素变化对锅炉运行各方面的影响。得到的结论对有利于进一步的优化运行并为今后设备改造和完善提供依据。
To optimize the performance of 310t/h petrol coke/coal fired CFB boiler, relative experiments were carried out. Mixing ratio of petrol coke/coal, proportion of primary/secondary air distribution, boiler load are the key parameters involved in this research. The effects of these factors on boiler' s operation and economic indexes were examined. The result is significant to operation optimization and possible improvement of equipments.
出处
《能源工程》
2005年第5期48-51,共4页
Energy Engineering
关键词
循环流化床锅炉
石油焦
混烧
运行特性
CFB( Circulating Fluidized Bed) boiler
petrol coke
co-firing