期刊文献+

A new type of inferior vena cava filter and its animal experiment

A new type of inferior vena cava filter and its animal experiment
下载PDF
导出
摘要 This article explains the definition of pulmonary embolism as well as its causes and elaborates on a new type of inferior vena cava filter(VCF)we have developed. Shaped like a waistdrum, the VCF is mainly made of TiNi shape memory alloy-wire. It has a subulate wire frame which can intercept the thrombus on each side. Its medial body is made up of straight shape memory alloy-wire . Every pillar is bound by several shape memory alloy springs. This type of inferior vena cava filter has a good resistance to fatigue and is hard to be broken. Through animal experiments its framework has been proved to be lasting. Neither deformation nor fragmentation happened when the VCF had been kept in the body for a long time. The thrombus interception efficiency of our VCF is higher than imported VCFs. The filter is unfavorable for thrombosis. After implantation, the IVC was completely unimpeded and no displacement occurred. Moreover the VCF did little damage to the Wall of vein. Neither IVC perforation nor haematoma occurred after the operation. This article explains the definition of pulmonary embolism as well as its causes and elaborates on a new type of inferior vena cava filter(VCF)we have developed. Shaped like a waistdrum, the VCF is mainly made of TiNi shape memory alloy-wire. It has a subulate wire frame which can intercept the thrombus on each side. Its medial body is made up of straight shape memory alloywire . Every pillar is bound by several shape memory alloy springs. This type of inferior vena cava filter has a good resistance to fatigue and is hard to be broken. Through animal experiments its framework has been proved to be lasting. Neither deformation nor fragmentation happened when the VCF had been kept in the body for a long time. The thrombus interception efficiency of our VCF is higher than imported VCFs. The filter is unfavorable for thrombosis. After implantation, the IVC was completely unimpeded and no displacement occurred. Moreover the VCF did little damage to the Wall of vein. Neither IVC perforation nor haematoma occurred after the operation.
出处 《广东有色金属学报》 2005年第2期356-361,共6页 Journal of Guangdong Non-Ferrous Metals
关键词 静脉滤波器 形状记忆合金 肺部 栓子 shape memory alloy inferior vena cava filter pulmonary embolism
  • 相关文献

参考文献3

二级参考文献16

  • 1任安,姜卫剑,黄振国,陆立,张雪哲,卢延.国人肾下段下腔静脉测量及分析[J].中华放射学杂志,1996,30(2):109-112. 被引量:12
  • 2Epstein DH, Darcy MD, Hunter DW, et al. Experience with the Amplatz retrievable vena cava filter. Radiology, 1989, 172:105-110.
  • 3Vesely TM, Krys J, Smith SR, et al. Preliminary investigation of the Irie inferior vena cava filter. J Vasc Interv Radiol, 1996, 7:529-535.
  • 4Schleich JM,Morla O,Laurent M,et al.Long-term follow-up of percutaneous vena cava filters: a prospective study in 100 consecutive patients[].European Journal of Vascular and Endovascular Surgery.2001
  • 5Decousus H,Leizorovicz A,Parent F,et al.A clinical trial of vena caval filters in the prevention of pulmonary embolism in patients with proximal deep-vein thrombosis[].The New England Journal of Medicine.1998
  • 6Grassi CJ,Swan TL,Cardella JF,et al.Quality improvement guidelines for percutaneous permanent inferior vena cava filter placement for the prevention of pulmonary embolism[].Journal of Vascular and Interventional Radiology.2001
  • 7David W,Gross WS,Colaiuta E,et al.Pulmonary embolus after vena cava filter placement[].The American Surgeon.1999
  • 8Athanasoulis CA,Kaufman JA,Waltman AC,et al.Inferior vena caval filters: review of a 26-year single-center clinical experience[].Radiology.2000
  • 9Greenfield LJ,Proctor MC,Mich AA.Recurrent thromboembolism in patients with vena cava filters[].Journal of Vascular Surgery.2001
  • 10Rogers FB,Strindberg G,Shackford SR,et al.Five-year follow-up of prophylactic vena cava filters in high-risk trauma patients[].Archives of Surgery.1998