期刊文献+

PCI时球囊扩张释放支架对QRS宽度和额面电轴的影响

Effects of Balloon Inflation to Implantation Stent on QRS Duration and Frontal Plane QRS Axis During Percutaneous Coronary Intervention
下载PDF
导出
摘要 【目的】探讨PCI时球囊扩张释放支架对心电图QRS时限及QRS额面电轴的影响。【方法】130例冠心病患者,观察球囊扩张释放支架前后QRS时限及QRS额面电轴的变化。【结果】左前降支球囊扩张释放支架后,QRS波时限延长(81.5±11.7 ms比94.0±12.9 ms,P<0.01)、QRS额面电轴左偏[(47.8±22.6)度比(26.0±34.8)度,P<0.01];右冠状动脉球囊扩张释放支架后,QRS时限延长[(81.5±11.40)ms比(93.7±12.6)ms,P<0.01]、QRS额面电轴右偏[(47.6±23.0)度比(64.1±24.6)度,P<0.01];左回旋支球囊扩张释放支架后QRS时限延长[(83.9±11.7)ms比(93.8±12.3)ms,P<0.01],对于左冠优势型的患者QRS额面电轴右偏[(48.7±20.9)度比(64.2±19.3)度,P<0.01],对于右冠优势型的患者QRS额面电轴左偏[(51.2±24.7)度比(30.6±25.4)度,P<0.01]。【结论】球囊扩张释放支架后,QRS时限延长及QRS额面电轴的变化可能是急性心肌缺血的标志。 [Objective]To investigate the effects of balloon inflation to implantation stent on QRS duration and frontal plane QRS axis during percutaneous coronary intervention. [Methods]QRS duration and frontal plane QRS axis were measured before and after balloon inflation to implantation stent in 130 patients with coronary artery disease during percutaneous coronary intervention. [Results]QRS duration was prolonged [from (81.5±11.7)ms to (94.0±12.9) ms, P 〈0.01] and frontal plane QRS axis was shifted to the left [from (47.8_±22.6) degrees to (26.0±34.8) degrees, P〈0.01] after balloon inflation to implantation stent in left anterior descending artery; QRS duration was prolonged [from (81.5±11.4) ms to (93.7±12.6) ms, P〈 0.05] and frontal plane QRS axis was shifted to the right [from (47.6±23.0) degrees to (64.1±24.6) degrees, P〈0.01] ,after balloon inflation to implantation stent in right coronary artery; QRS duration was prolonged [from (83.9±11.7) ms to (93.8±12.3) ms, P 〈0.05] and frontal plane QRS axis was shifted to the right [from (48.7±20.9) degrees to (64.2± 19.3) degrees, P 〈0.01] for patients with the dominant left coronary artery and to the left [from (51.2±24.7) degrees to (30.6±25.4) degrees, P 〈0.01] for the patients with the dominant right coronary artery after balloon inflation to implantation stent in left circumflex artery. [Conclusion]QRS prolongation and frontal plane QRS axis deviation after balloon inflation to implantation stent in coronary artery may be a marker of myocardial ischemia.
出处 《医学临床研究》 CAS 2005年第11期1540-1542,共3页 Journal of Clinical Research
关键词 血管成形术 经腔 经皮冠状动脉 支架 心电描记术 angioplasty, transluminal, percutaneous coronary stents electrocardiography
  • 相关文献

参考文献9

  • 1叶新和,骆秉铨,胡大一,魏顺光,柴湘枢.胺碘酮对豚鼠缺血缺氧心肌细胞电生理影响的研究[J].中国心脏起搏与心电生理杂志,2000,14(3):215-216. 被引量:10
  • 2Veenstra RD,Joyner RW,Rawling DA,et al.Purkinje and ventricular activation sequences of canine papillary muscle:effects of quinidine and calcium on the Purkinje-ventricular conduction delay[J].Circ Rec,1984,54:500-508.
  • 3Cantor A, Goldfarb B, Aszodi A,et al.QRS prolongation measured by a new computerized method: a sensitive marker for detecting exercise-induced ischemia[J].Cardiology, 1997, 88: 446-452.
  • 4詹中群,李增高,殷跃辉,王崇全,王玮.QTpd及QRS宽度和QRS额面电轴在冠心病患者运动试验中的意义[J].临床心血管病杂志,2003,19(10):596-598. 被引量:2
  • 5Madias JE, Attari M, Demetrius B,et al.Wave in a patient with an acute inferior myocardial infarction[J].J Electrocardiol,2001, 34:173-177.
  • 6Schick EC, Weiner DA, Hood WB, et al. Increase in R-wave amplitude during transient epicardial injury(Prinzmetal type)[J].J Electrocardiol,1980, 13:259-266.
  • 7Wagner NB, Sevilla DC, Krucoff MW, et al. Transient alterations of the QRS complex and ST segment during percutaneous transluminal balloon angioplasty of the right and left circumflex artery[J].Am J Cardiol, 1989, 63:1208-1213.
  • 8Man-Hong Jim, Chung-Wah Siu, Stephen Wai-Luen Lee,et al. Transient giant R-wave, right axis deviation, and intraventricular conduction delay during exercise treadmill testing: a case report[J].J Electrocardiol, 2004, 37:61-66.
  • 9Barnhill JE, Wikswo JP, Dawson AK, et al. The QRS complex during transient myocardial ischemia: studies in patients with variant angina pectoris and in a canine preparation[J].Circulation, 1985,71:901-911.

二级参考文献8

  • 1Shirota K, Ogino K, Hoshio A, et al. Changes of ORS axis in transient myocardial ischaemia induced by percutaneous transluminal coronary angioplasty. Eur Heart J, 1994,15 : 1391- 1395.
  • 2Stoletniy L N, Pai R G. Value of QT dispersion to the accuracy of an exercise stress in women. Circulation, 1997,96:904-910.
  • 3Ulgen M S, Kalade A, Alan S, et al. Contribution of the peak exercise QT dispersion to the accuracy of an exercise test during the evaluation of coronary artery disease. Aeta Cardiol, 2000,55 : 335- 339.
  • 4Zabel M, Franz M R, Klingenheben T, et al. Rate-dependence of QT dispersion and the QT interval:comparison of atrial pacing and exercise testing. J Am Coll Cardiol, 2000,36 : 1654- 1658.
  • 5Veenstra R D, Joyner R W, Rawling D A, et al. Purkinje and ventricular activation sequences of canine papillary muscle: effects of quinidine and calcium on the Purkinje-ventricular conduction delay. Circ Rec, 1984, 54:500-515.
  • 6Cantor A, Goldfarb B, Aszodi A,et al. QRS prolongation measured by a new computerized method: a sensitive marker for detecting exercise-induced ischemia. Cardiology, 1997, 88: 446- 452.
  • 7Shiran A, Halon D A, Merdler A, et al. Accuracy of exercise-induced left axis QRS deviation as a specific marker of left anterior descending coronary artery disease. Cardiology, 1998,89: 297-302.
  • 8叶新和,骆秉铨,胡大一,魏顺光,柴湘枢.胺碘酮对豚鼠缺血缺氧心肌细胞电生理影响的研究[J].中国心脏起搏与心电生理杂志,2000,14(3):215-216. 被引量:10

共引文献10

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部