摘要
During the preparation of the iodide-iodate solution I - was oxidized,which caused large deviation of calculated segregation index from experimental value.In this paper, the concentrations of I-<sub>3,I- and I2 in as-prepared solution were determined through concentration analysis of I- <sub>3 by spectrophotometer, and then the oxidized amount of I- was calculated. A modified expression of segregation index for iodide-iodate reaction system wa s deduced and verified by experiments, indicating that the deviation between exp erimental results and the modified expression was within ±15%.
During the preparation of the iodide-iodate solution Ⅰ^- was oxidized, which caused large deviation of calculated segregation index from experimental value. In this paper, the concentrations of Ⅰ3^-,Ⅰ^- and Ⅰ2 in as-prepared solution were determined through concentration analysis of Ⅰ3^- by spectrophotometer, and then the oxidized amount of Ⅰ^- was calculated. A modified expression of segregation index for iodide-iodate reaction system was deduced and verified by experiments, indicating that the deviation between experimental results and the modified expression was within ±15%.
出处
《化工学报》
EI
CAS
CSCD
北大核心
2005年第10期1856-1859,共4页
CIESC Journal
关键词
离集指数
微观混合
浓度分析
segregation index
micromixing
concentration analysis