期刊文献+

柳林电厂410 t/h锅炉水冷壁腐蚀原因分析及预防 被引量:3

The Decay Reasons and Prevention about the Cold Water Wall in410 t/h Boiler in LiuLin Power Plant
下载PDF
导出
摘要 针对柳林电厂410 t/h高压锅炉水冷壁腐蚀情况进行原因分析,认为炉内燃烧组织不佳、局部缺氧燃烧严重,当煤粉中硫的含量较大时还原性气氛形成的高温腐蚀。通过采用热喷涂、燃烧调整有效地解决了水冷壁的高温腐蚀。 It analyzes the reasions of heat decay in the power plant. That the burn states in Boiler is not good, the in coal is very much, are the main reasions of heat decay. electricity sprays to draw and the burn adjusting. (;old Water Wall in the 410 t/h high pressure Boiler anoxia burn in some parts is very serious, the sulphur component The question of heat decay is settled efficiently by the way of
出处 《山西电力》 2005年第6期25-26,33,共3页 Shanxi Electric Power
关键词 水冷壁 高温腐蚀 防范措施 电弧喷涂 the cold water wall heat decays measure of prevention electric sprays to draw
  • 相关文献

同被引文献5

引证文献3

二级引证文献11

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部