摘要
论述了天荒坪抽水蓄能电站地下厂房送排风形式模拟试验的模化分析及模型设计等内容。并介绍了对多种送排风形式的试验结果。
A simulating test of air spply mode and air return mode for the underground work shop of Tianhoungpin pumped hydroelectric powec station is studied.It mainly gives the simulating analysis and simulating design for making the test mould. From the test we get the optimum air supply mode and air returnmode in this work shop.
出处
《西安建筑科技大学学报(自然科学版)》
CSCD
1996年第2期210-214,共5页
Journal of Xi'an University of Architecture & Technology(Natural Science Edition)
关键词
抽水蓄能水电站
地下式厂房
送风
排风
模拟试验
pumped hydroelectric power' station, underground work shop air supply mode, air returnmode, air dirtribution, air conditioning system