期刊文献+

尼尔雌醇的荧光光谱法研究与应用 被引量:4

Studies on nilestriol with fluorescence spectrometry
下载PDF
导出
摘要 系统研究了用荧光光谱法测定尼尔雌醇的争件。发现在中性条件下,β-CD能显著增敏荧光,探讨了作用机理,提出了测定尼尔雌醇的高灵敏度荧光光谱分析新方法。体系的线性范围为2.63×10^-7~1.84×10^-5mol/L,检出限为9.4×10^-8mol/L。已用于市售尼尔雌醇片剂样品的分析。 In this paper, different conditions for the determination of nilestriol with fluorescent spectrometry were investigated. It was found that β-cyclodextrin could enhance the fluorescence intensity greatly under neutral situation, thus a simple and highly sensitive approach was put forward with the linear range of 2.63×10^-7~1.84×10^-5mol/L and the detection limit of 9.4×10^-8mol/L, which has been successfully applied to the determination of nilestriol in tablets. The results were satisfactory.
出处 《分析试验室》 CAS CSCD 北大核心 2006年第1期20-23,共4页 Chinese Journal of Analysis Laboratory
基金 国家自然科学基金资助项目(20275028)
关键词 尼尔雌醇 荧光光谱 包络物 药物分析 Nilestriol Fluorescent spectrometry Inclusion Complex Pharmaceutical analysis
  • 相关文献

参考文献3

二级参考文献8

共引文献7

同被引文献71

引证文献4

二级引证文献30

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部