摘要
简要叙述了在动态回路装置上对电磁过滤器净化性能的研究,包括励磁强度、通水流速、进水中杂质浓度、滤床高度和氧化物形态对净化性能的影响以及净化容量和再生工艺参数的测定。并给出了热电厂验证电磁过滤器净化性能的试验结果。
This paper describeds the investigation on the purification performance of electromagnetic filter in the dynamic loop facility,which includs an influences of field density,flow velocity of water,concentration of enter water,height of filter bed and form of oxide on the purification performance of electromagnetic,and determination purification capacity and regeneration tech- nology parameter,also give the results tested in thermal power plant for demonstrates the pu- rification performance of electromagnetic filter.
出处
《核动力工程》
EI
CAS
CSCD
北大核心
1996年第1期78-83,共6页
Nuclear Power Engineering
关键词
反应堆
电磁过滤器
净化性能
水处理
核电厂
Reactor
Electromagnetic filter
Purification performance
Water treatment