摘要 对竖井管式絮凝反应器作了大量实验研究,发现聚合氯化铝投加量为25~45mg/L时,对城市生活污水有较好的处理效果,COD去除率可以达到65%左右,总磷去除率达55%~70%,浊度去除率达85%左右。运行时借助于水位落差和水力学作用,可以不需要其他搅拌设备,耗能少,占地小,有较强的推广价值。适合对城市污水的预处理,也适合于与生物法相结合,提高脱磷效果。 Vertical-piped flocculation reactor was studied a lot in this paper. The reactor showed good disposal effect on municipal sewage when the of polymeric aluminum chloride (PAC) was just 25 - 45 mg/L. COD removal ratio achieved about 65% ;total phosphorus removal ratio achieved 55% - 70%, turbidity removal ratio achieved about 85%. Because it recurs to water level fall and hydraulics effects,it can run without other mixing facilities. As the reactor is economic and utility, it is worthy to be generalized. The reactor fits municipal sewage pretreatment, and it can also be used together with biologic method to enhance phosphorus removal efficiency of the latter.
出处 《应用化工》 CAS CSCD 2006年第2期157-159,共3页 Applied Chemical Industry
基金 国家十五863课题(2003AA601110)
关键词 城市污水 聚合氯化铝 絮凝器 municipal sewage polymeric aluminum chloride flocculation reactor
  • 相关文献

参考文献6

二级参考文献21

  • 1张雨虹.密封系统中冲洗液粒子的分离[J].流体工程,1993,21(6):33-38. 被引量:12
  • 2阮复昌,公国庆,莫炳禄,卢燕玲.改性聚合硫酸铁的絮凝特性及其应用[J].环境工程,1996,14(5):14-17. 被引量:17
  • 3Mogens Henze 国家城市给水排水工程技术研究中心(译).污水生物处理与化学处理技术[M].北京:中国建筑工业出版社,1999..
  • 4贾能铀,净水技术,1993年,1期,24页
  • 5马青山,絮凝化学和絮凝剂,1988年
  • 6郑兴灿,污水除磷脱氮技术[ M],1998年
  • 7陈茅章.粘性流体动力学理论及紊流工程计算[M].北京:北京航空学院出版社,1986.221.
  • 8王绍文.论混凝的动力致因[A]..给水与废水处理国际会议论文集[C].,1994.186—190.
  • 9殷友庭.紊流混凝动力学模式的建立、运用和开发[J].华东给水排水,1991,(2).
  • 10严照世.水和废水技术研究[M].北京:中国建筑工业出版社,1992(3)..

共引文献321

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部