期刊文献+

泛比电阻电除尘器除尘性能试验 被引量:4

TEST OF COLLECTION DUST CAPABILITY OF EXTENSIVE RESISTIVITY ELECTROSTATIC PRECIPITATOR
下载PDF
导出
摘要 泛比电阻电除尘器是一种具有辅助电极和交错平板阳极的新型电除尘器,实验室冷态模拟试验结果表明,泛比电阻电除尘器的除尘性能明显优于原式电除尘器和常规电除尘器,其驱进速度改善系数为1.30~1.33,节能达14%~32%,而且对粉尘浓度的变化有良好的适应性。 Extensive resistivity electrostatic precipitator is a new type ESP with assistant electrodes and interlaced collection plates.In the lab conditions, cold-state simulated tests of extensive resistivity ESP have been done, the test results show that the collection dust capability of extensive resistivity ESP is better than the HARRAR ESP'S and the common ESP'S.The closed-velocity's modified coefficients of extensive resistivity ESP are in the range of 1.30 to 1.33, and energy consuruption is reduced by 14% to 32%. What's more, extensive resistivity ESP can adapt the changeable dust concentration.
出处 《环境工程》 CAS CSCD 北大核心 2006年第1期41-42,共2页 Environmental Engineering
基金 国家科技部专项资金资助项目(NCSTE2002JKZX043)
关键词 泛比电阻电除尘器 模拟试验 除尘性能 extensive resistivity electrostatic precipitator, simulated test, collection dust capability
  • 相关文献

同被引文献93

引证文献4

二级引证文献52

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部