总结了用于计算CO2超临界状态下换热和压降的关联式,与相关文献中的实验数据进行了比较,结果表明Pettersen修正的换热关联式和Yin修正的换热关联式偏差较小,Churchill的压降关联式偏差最小。
Presents common heat transfer and pressure drop correlations, and compares them with experimental data from literatures, The results indicate that Pettersen's and Yin's modifications of heat transfer correlations and Chuichill's pressure drop correlation have less deviation than the other correlations,
出处
《暖通空调》
北大核心
2006年第3期25-28,共4页
Heating Ventilating & Air Conditioning
基金
国家重点基金研究项目(编号:G2000026303)
关键词
CO2超临界冷却
换热
压降
关联式
实验数据
偏差