期刊文献+

横向磁场直线开关磁阻电机换相位置的间接检测方法 被引量:1

Indirect Detecting Method of Commutation Position for Transverse Flux Linear Switched Reluctance Motor
下载PDF
导出
摘要 针对横向磁场直线开关磁阻电机(TFLSRM)的结构,利用各相绕组磁链在磁极中随位置不同而产生的差异,提出了一种TFLSRM换相位置间接检测方法。该方法只需在初级边附加一套具有独立磁路的三相检测绕组,即可获得各相换相位置参考点,并能克服电机启动前各检测绕组磁链恒定不变而无法确定上升区与下降区的不足。结果表明,所提方法可方便地实现对TFLSRM换相位置的检测。 In the light of the structure of TFLSRM, an indirect detecting method of commutation position is given by use of the flux differences of different phase of windings as the position changes. By adding of a 3-phase detecting winding with independent magnetic circuit in primary side, the reference point for commutation of each phase could be achieved. And the defects could be removed that raising or dropping zone could not be determinod due to the constant flux of each detecting winding before the motor start-up. The results show that with the proposed method the commutation position could be easily detected.
出处 《机车电传动》 2006年第2期49-52,共4页 Electric Drive for Locomotives
基金 教育部重点项目(2004104051) 台达电力电子科教发展基金计划(DREG2005006) 北京交通大学"十五"专项科技基金(2003SM013)资助
关键词 横向磁场 直线电机 开关磁阻电机 间接检测方法 transverse flux linear motor switched reluctance motor indirect detecting method
  • 相关文献

参考文献8

二级参考文献12

  • 1邱亦慧 詹琼华 马志源 等(Qiu Yihui Zhan Qionghua Ma Zhiyuan etal).基于简化磁链法的开关磁阻电机间接位置检测(Theindirect position sensing of SRM onthe basis ofsimplifiedflux method)[J].中国电机工程学报(ProceedingsoftheCSEE),2000,.
  • 2[3]Acamley P P, Hooper C W. Detection of rotor position in stepping and switched motors by monitoring of current waveforms [J]. IEEE Trans. on Industrial Electronics,1985,3(22):215-222.
  • 3[5]Ehsani M. New modulation encoding techniques for indirect rotor position sensing in switched reluctance motors [J]. IEEE Trans. on Industry Application,1994,30(1):85-91.
  • 4[6]Ehsani M, Husain I, Kulkami A B. Elimination of discrete position sensor and current sensor in switched reluctance motor drives [J].IEEE Trans. on Ind. Appl.,1992,(1):128-135.
  • 5Ehsani Mehrdad,IEEE Trans IA,1992年,28卷,1期
  • 6Ma Binyen,IEEE Trans Aerospace Electronic Systems,1998年,34卷,4期
  • 7Perl T. Design Trends and Trade- offs for Sensorless Operation of Switched Reluctance Motor Drives[C].IEEE Proc. of IAS Annual Meeting,1995:278-285
  • 8毛良明,经亚枝,樊小明,张焕春.开关磁阻电动机的无位置检测方案评述[J].测控技术,1997,16(3):51-54. 被引量:8
  • 9樊小明,经亚枝,张焕春,毛良明.开关磁阻电机的一种无位置检测器方案的研究[J].电工技术学报,1997,12(6):27-31. 被引量:13
  • 10詹琼华,王双红,肖楚成.开关磁阻电动机电容式位置检测技术[J].电工技术学报,1999,14(3):1-5. 被引量:17

共引文献57

同被引文献16

  • 1陈坤华,孙玉坤,吴建兵,黄振跃.基于电感模型的开关磁阻电机无位置传感技术[J].电工技术学报,2006,21(11):71-75. 被引量:23
  • 2CAI Jun, DENG Zhiquan. Sensorless control of switched reluctance motor based on phase inductance vectors [ J]. IEEE Transactions on Power Electronics,2012,17 ( l 0 ) :34 l0 - 3423.
  • 3KRISHNAMURTHY M,EDRINGTON C S,FAHIMI B. Prediction of rotor position at standstill and rotating shaft condition in switched reluctance machines [ J ]. IEEE transactions on power e- lectronics,2006,21 ( 1 ) : 225 -233.
  • 4GAO Hongwei, SALMASI F R, EHSANI M. Imtuctance model- based sensorless control of the switched reluctance motor drive at low speed[J]. IEEE Transactions on Power Electronics,2004,19 (2) :1568 - 1573.
  • 5GALLEGOS-Lopez G, KJAER P C, MILLER T J E. High-grade position estimation for SRM drives using flux linkage/current cor- rection model [ J ]. IEEE Transactions on IA, 1998,34 ( 4 ) : 859 - 869.
  • 6SURESH G, FAHIMI B, RAHMAN K M, el al. Inductance based position encoding for sensorless SRM drives [ C ]//Power Electron- ics Specialists Conference,June 27,1999, Charleston, USA. 1999 : 832 - 837.
  • 7LUMSDAINE A, LANG J H. State observers flr variable-reluc- tance motors[J]. IEEE Transactions on Industrial FAectronics, 1990,37(2) :133 - 142.
  • 8EHSANI M, HUSAIN I, MAHAJAN S, et al. New modulation en- coding techniques for indirect rotor position sensing in switched reluctance motors [ J]. IEEE Transactions on Industry Applita- tions, 1994,30 ( 1 ) :85 - 91.
  • 9BATEMAN C J,MECROW B C. Sensorless operation of an ultra- high-speed switched ~luetance machine [ J]. IEEE Transatinns on Industry Applications,2010,46 (6) : 2329 - 2337.
  • 10ZHONG R, WANG Y B, XU Y Z. Position sensorless contrail of switched reluctance motors based on improved neural network [ J ]. IET Electric Power Applications, 2012,6 ( 2 ) : 11 1 - 12 1.