摘要 分析了矢量网络分析仪测试系统的误差来源,给出二端口SOLT校准的12项误差模型,由此推导了待测元件的真实S参数,并且详细讲述了SOLT校准件的制作方法,确定出开路件的边缘电容。最后,使用自制的PCB夹具测量了0603封装的电感和电容,对校准前后的测量数据进行了对比、分析,并成功地提取了封装后的模型参数,结果证明该方法可以用于射频夹具测量的校准。 The sources of errors in the vector network analyzer measurements are presented, and a total of 12 errors for two-port SOLT calibration are shown, then the actual device S-parameters are derived from the measured S-parameters. The complete procedure for designing SOLT (short, open, load, thru) calibration standards is given, and we characterize the fringing capacitance of the open standard. In addition, we measure a 0603 inductor and a 0603 capacitor using the PCB fixture designed before, then, we contrast the measurement data after calibration with that before calibration, extract their extrinsic models successfully. It is found that this method is effective for the fixture calibration for RF application.
作者 叶荣芳 徐佳
出处 《电子器件》 EI CAS 2006年第1期179-182,共4页 Chinese Journal of Electron Devices
关键词 校准 SOLT方法 S参数测量 夹具 calibration SOLT method S parameters measurements fixture
  • 相关文献

参考文献4

  • 1Agilent E5070B/E5071B ENA Series RF Network Analyzers User's Guide[S],Third Edition,Agilent Part No.E5070-90050,July 2003.
  • 2HighSpeed Board Design Techniques[Z],Copyright 1997 Advanced Micro Devices,Inc.
  • 3Agilent In-Fixture Microstrip Device Measurements Using TRL Calibration[S],Agilent Product Note PN 8720-2.
  • 4Naishadham K.Measurement-Based Closed-Form Modeling of Surface-Mounted RF Components[J].IEEE Trans Microwave Theory Tech,October 2002,50(10).

同被引文献50

引证文献8

二级引证文献19

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部