期刊文献+

骨水泥强化动力髋固定效果的生物力学研究 被引量:14

Biomechanical evaluation of the dynamic hip screw with bone cement augmentation
下载PDF
导出
摘要 目的:研究A2型股骨转子间骨折动力髋螺钉(DHS)固定加骨水泥强化对内固定生物力学影响。方法:24对成年男性防腐股骨上段标本,制造A2型股骨转子间骨折,采用4孔DHS固定。每对股骨以左侧为非强化组,右侧为强化组,股骨头髓腔钉道填塞骨水泥。标本进行弯曲强度,扭转强度及破坏试验。测量骨折位移,转角及最大加载力。结果:强化组和非强化组在弯曲强度,扭转强度及最大加载力有显著差异(P<0.05),有统计学意义。相对于非强化组,骨水泥强化后弯曲强度提高148%,扭转强度提高96%,最大加载力提高67%。结论:骨水泥强化有效地增加DHS固定强度,整体提高骨折稳定性,减少内固定失败的可能性。 Objective: To evaluate the biomechanical effects of the dynamic hip screw (DHS) augmented with bone cement in A2 intertrochanteric fractures. Methods: Twenty-four matched pairs of embalmed male upper femora were used. All the specimens which were created unstable Type A2 intertrochanteric fracture were fixed by a four-hole DHS. The left one from each pair was designated as unaugmented team, whereas the right femur served as the augmented team. The bone cement was injected into the hip screw track. Within a servohydraulic testing machine,femoral specimens were fixed to perform the biomechanica! test which included the bending stiffness, torsional stiffness and the greatest loading .The load was increased to measure the displacement of the fracture, torsional angel and the strength to the failure. Results: There was significant difference (P〈 0.05) of the biomechanical effects between the augmented team and the unaugmented one. With bone cement augmentation, the bending stiffness increased by 148 percent, torsional stiffness increased by 96 percent and the greatest loading increased by 67 percent. Conclusions: Augmenting fixation with PMMA increase the intensity through improving significantly overall stability of the fracture, thereby decrease the risk of screw cutout.
出处 《中国临床解剖学杂志》 CSCD 北大核心 2006年第2期204-206,共3页 Chinese Journal of Clinical Anatomy
关键词 股骨 转子间骨折 动力髋 骨水泥 骨质疏松 生物力学 femoral intertrochanteric fracture DHS bone cement osteoporosis biomechanics
  • 相关文献

参考文献7

  • 1Sommers MB,Roth C,Hall H,et al.A laboratory model to evaluate cutout resistance of implants for pertrochanteric fracture fixation[J].J Orthop Trauma,2004,18(6):361~368.
  • 2Kim WY,Han CH,Park JI,et al.Failure of intertrochanteric fracture fixation with a dynamic hip screw in relation to pre-operative fracture stability and osteoporosis[J].Int Orthop,2001,25(6):360~362.
  • 3Stromsoe K.Fracture fixation problems in osteoporosis[J].Injury,2004,35(2):107~113.
  • 4卢世璧,主译.坎贝尔骨科手术学(第9版)[M].济南:山东科学技术出版社,2004.2133~2148.
  • 5柯楚群,林英权,许知光,梁观宝,黄新宇,赵卫东.骨水泥固定桡骨远端不稳定性骨折的生物力学研究[J].中国临床解剖学杂志,2001,19(3):272-273. 被引量:3
  • 6Augat P,Rapp S,Claes L.A modified hip screw incorporating injected cement for the fixation of osteoporotic trochanteric fractures[J].J Orthop Trauma,2002,16(5):311~316.
  • 7Wu CC,Shih CH,Lee MY,et al.Biomechanical aAnalysis of location of lag screw of a dynamic hip screw in treatment of unstable intertrochanteric fracture[J].J Trauma,1996,41 (4):699~702.

二级参考文献7

  • 1胡清潭 曾志军 等.经皮克氏针治疗桡骨远端骨折[J].骨与关节损伤杂志,1999,14(1):46-7.
  • 2王亦璁,创伤早期处理,1994年,211页
  • 3胡清潭,骨与关节损伤杂志,1999年,14卷,1期,46页
  • 4马元璋,临床骨内固定学,1999年,217页
  • 5吕厚山,人工关节外科学,1998年,527页
  • 6张抒,侯春林.桡骨远端关节内骨折治疗进展[J].中国矫形外科杂志,1998,5(1):67-68. 被引量:4
  • 7敖新华.2110例老年人骨折流行病学分析[J].骨与关节损伤杂志,2000,15(2):142-143. 被引量:20

共引文献2

同被引文献188