期刊文献+

两种干涉条纹视力计对白内障患者术后视力预测的对照研究 被引量:3

Comparison of domestic interferometer with Heine interferometer for the assessment of potential visual acuity in cataractous eyes
下载PDF
导出
摘要 目的通过国产干涉条纹视力计与Heine干涉条纹视力计在预测白内障患者术后视力中的应用对比,探讨国产干涉条纹视力计预测白内障患者术后视力的准确性、实用性、可行性。方法将71例(92眼)白内障患者平均分成2组,术后的视功能情况分别用国产干涉条纹视力计与Heine干涉条纹视力计2种方法进行预测,结果与患眼术后最佳矫正视力进行相关性分析对比。结果国产干涉条纹视力计预测的准确率为81.0%(预测视力与术后视力相差2行以内者认为准确),平均预测视力(4.695)与平均术后最佳矫正视力(4.771)比相差不到1行。Heine干涉条纹视力计预测的准确率为43·9%,平均预测视力(4.481)与平均术后最佳矫正视力(4.771)比相差约3行。结论比起Heine干涉条纹视力计,国产干涉条纹视力计检查更能合理的反映视觉功能,对白内障术后视力具有较好的预测性。 Objective To assess the veracity, practicability, feasibility of domestic interferometer through comparing it with the Heine interferometer. seventy-one cataract patients (ninety-two eyes) were divided into two groups. The potential visual acuities (PVA) were assessed by domestic interferometer and Heine interferometer. The results were compared with their best corrected visual acuity(BCVA).Results The accuracy of the domestic interferometer in predicting visual acuity posttreatment was 81.0% ( difference between PVR and BCVA in two lines were regarded as accuracy), The predicted visual acuity(4. 695) of the domestic interferorneter was inaccurate by an average of less than one line lower comparing with BCVA ( 4. 771 ). The accuracy of the Heine interferometer in predicting visual acuity posttreatmeut was 43.9% . The predicted visual acuity(4. 481)was inaccurate by an average of almost 3 lines lower comparing with BCVA (4.771). Conclusion Domestic interferometer can predict visual acuity more reasonably than Heine interferometer. It is a useful instruction to predict visual acuity after cataract surgery.
出处 《眼科新进展》 CAS 2006年第4期283-286,共4页 Recent Advances in Ophthalmology
基金 温州市科技计划项目(编号:G2003005)
关键词 干涉条纹视力计 白内障 视力预测 最佳矫正视力 interferance visual acuity cataract potent visual acuity best corrected visual acuity
  • 相关文献

参考文献4

二级参考文献21

  • 1陈君平,熊端华,宋文熹,陈开达,吴奇慧.激光干涉条纹视力测定对弱视疗效的预测[J].中华眼科杂志,1994,30(4):283-285. 被引量:7
  • 2李金海,游光华.新型激光视网膜MTF测定仪的光学设计[J].应用激光,1995,15(1):39-40. 被引量:5
  • 3冯郁芬.用全息光学元件测定视网膜功能的新装置.应用激光,1984,4(1):39-40.
  • 4孙文德.视网膜视觉锐度的激光测定.应用激光,1984,4(1):41-43.
  • 5徐德衍 伍树东 王永龄.用光栅干涉测定视觉锐度的新技术.光学学报,1983,(8):762-764.
  • 6汪芳润.激光干涉条纹视力测定与应用[J].中华眼科杂志,1987,26(3):151-153.
  • 7金成鹏 陈式苏.激光干涉法测定视网膜功能[J].中国生物医学工程学报,1984,3(3):186-188.
  • 8Binder PS,Ayazuddin M,Hintze R.Visual prognosis for corneal transplantation based on preoperative visual evoked potential and electroretinogram[J].Ophthalmology 1982;89(6):661-667.
  • 9Fukuhara J,Uozato H,Morioka T.Studies on visual evoke potentials elicited by laser speckle pattern.VI.Assessment of macular function in cataract[J].Jpn J Clin Ophthalmol 1983;37(6):737-742.
  • 10Nomura M,Mashima Y,Matsuhashi M.Simultaneous VEP and ERG recording in patients with media opacities diabetic retinopathy[J].Folia Ophthalmol Jpn 1986;37(8):1234-1238.

共引文献58

同被引文献25

引证文献3

二级引证文献5

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部