摘要
介绍了液体自动颗粒计数器的工作原理、影响颗粒计数器测试准确性的参数及仪器校准方法新老标准的差异,论述了尺寸校准的作用、方法以及使用不同校准方法应采用不同的污染度等级标准。
The principle of the liquid automatic particle counter and the parameters for influencing the particle counter accuracy were introduced, and the differences of the new and old standards for the instrument calibration were enumerated. The function and method of size calibration, and that the appropriate particle contamination level standards should be used for the different calibration methods were discussed.
出处
《润滑油》
CAS
2006年第2期57-61,共5页
Lubricating Oil
关键词
自动颗粒计数器
校准
标准
液压油
liquid automatic particle counter
calibration
standard
hydraulic oil