期刊文献+

无除湿预处理采样法测定烟气中低浓度SO_2

Measurement of low SO_2 concentration in flue gas without pretreatment
下载PDF
导出
摘要 针对海水脱硫后的烟气具有SO2浓度低、湿度大、温度低的特点,提出了在烟道内无需除湿预处理的直接采样测定SO2的方法,解决了国标法进行除湿采样或使用较先进仪器直接脱水测定带来的测定结果偏低问题。实际应用表明,该法比在烟道外使用的除湿法更加准确、经济。 The flue gas which was treated by seawater adsorption process has the character of low SO2 concentration, high humidity and low temperature, The standard method for sampling SO2 can not be used and the SO2 concentration can not be rnonitored with electric equipment directly because the condensation of steam in flue gas can influence on SO2 concentration and make the measurement result be lower, To avoid the condensation of steam, a new sampling method without any pretreatment is developed. The result indicates that the SO2 measurement result can be more accurate with this new sampling method than the others. Moreover, this method's feasibility and merit is discussed deeply in theory.
出处 《电力环境保护》 2006年第2期54-56,共3页 Electric Power Environmental Protection
关键词 无除湿 采样 低浓度SO2 烟道气 sampling low SO2 concentration flue gas
  • 相关文献

参考文献4

二级参考文献5

  • 1樊保国.循环流化床烟气脱硫技术的试验研究[M].北京:清华大学,1996..
  • 2国家环保局《空气和废气监测分析方法》编写组.空气和废气监测分析方法[M].北京:中国环境科学出版社,1990.124-127.
  • 3胡厚钧.烟气脱硫装置性能测试技术的探讨.大气环境科学技术进展[M].北京:中国环境科学学会大气环境分会,1998.671-675.
  • 4胡厚钧,大气环境科学技术进展,1998年,671页
  • 5国家环保局《空气和废气监测分析方法》编写,空气和废气监测分析方法,1990年,356页