摘要
对Fenton试剂氧化处理印染废水进行了研究。考察了反应时间、双氧水投加量、硫酸亚铁投加量及PH值对印染废水的色度及COD去除率的影响。通过对印染废水进行正交实验及单因素分析实验,确定了Fenton试剂处理此印染废水的最佳实验条件。
Oxidation treatment of printing and dyeing waste water by Fenton reagent was studied in this paper. Effects of reaction time, added amount of FeSO4 and H2O2,Hp on the removal rate of chroma and COD of printing and dyeing waste water were analysed. At last, the best reaction conditions were determined by orthogonal test and single factor analysis experiment. Key words: