摘要 利用合肥800MeV电子存储环同步辐射(HESYR)作为紫外-真空紫外光谱辐射测量的绝对标准,标定了传递标准-氘灯光源的光谱辐亮度。采用德国国家物理技术研究院(PTB)的数据处理及不确定度分析方法,得到了两支氘灯在115~300nm波段的光谱辐亮度数据,其相对定标不确定度为12.1%。详细分析了相关参量对定标不确定度的贡献,指出辐射计量系统偏振特征量的不确定度贡献最大。在164~300nm波段,德国德国国家物理技术研究院在BESSYⅡ同步辐射装置上标定的绝对光谱辐亮度值与本实验在中国合肥同步辐射装置上标定的绝对光谱辐亮度值之间一致性优于±20%,在给定的不确定度范围内两光谱辐射标准定标结果一致。 The spectral radiance of transfer standard.deuterium lamp is calibrated using Hefei 800 MeV electron storage ring synchrotron radiation (HESYR) as an absolute UV-VUV spectral radiometric standard. The data processing and uncertainty analysis method of PTB is employed, in 115-300 nm the spectral radiance values of two deuterium lamps are obtained, and the overall uncertainty for D2 lamp calibration is 12.1%. A detailed analysis of the contributions to this uncertainty points out that the major part is caused by the uncertainty of the polarization properties of the radiometric instrumentation. In the range of 164 - 300 nm the D2 lamp absolute spectral radiant distribution obtained using HESYR China and that derived from BESSY Ⅱ Germany have a discrepancy within ± 20 %. They are consistent within the given uncertainties.
出处 《光学学报》 EI CAS CSCD 北大核心 2006年第4期541-546,共6页 Acta Optica Sinica
关键词 光谱辐射定标 合肥800 MeV同步辐射 紫外-真空紫外光谱辐射标准 光谱辐射亮度 氘灯 spectral radiometric calibration Hefei 800 MeV synchrotron radiation UV-VUV spectral radiometric standard spectral radiance deuterium lamp
  • 相关文献

参考文献11

  • 1李志刚,王淑荣,李福田.紫外-真空紫外傅里叶变换光谱仪[J].光学学报,2001,21(4):459-462. 被引量:8
  • 2高鸿奕,陈建文,谢红兰,朱化风,李儒新,徐至展,朱佩平,袁清习,田玉莲,黄万霞,王寯越,郑欣,冼鼎昌.X射线衍射增强相衬成像的实验结果[J].光学学报,2004,24(8):1151-1152. 被引量:8
  • 3李照洲,郑小兵,吴浩宇,李双,王乐意,乔延利.高精度光谱辐射标准探测器的温度特性研究[J].光学学报,2004,24(3):401-407. 被引量:13
  • 4D. Arnold , G. Ulm. Electron storage ring BESSY as a source of calculable spectral photon flux in the X-ray region[J]. Rev. Sci.Instrum. , 1992, 63(1): 1539-1542
  • 5M. Richter, J. Hollandt, U. Kroth et al.. Source and detector calibration in the UV and VUV at BESSY Ⅱ[J]. Metrologia,2003, 40:S107-S110
  • 6J. Fischer, M. Kuhne, B. Wende. Spectral radiant power measurements of VUV and soft X-ray sources using the electron storage ring BESSY as a radiometric standard source[J]. Appl.Opt., 1984, 23(23): 4252-4259
  • 7J. Schwinger. On the classical radiation of accelerated electrons [J]. Phys. Rev. , 1949, 75:1912-1921
  • 8邢进,王淑荣,李福田.紫外-真空紫外辐射标准光源的比对[J].光学精密工程,2004,12(4):373-379. 被引量:13
  • 9R. D. Saunders, W. R. Ott, J. M. Bridges. Spectral irradiance standard for the ultraviolet: the deuterium lamp [J]. Appl.Opt., 1977, 17(4), 593-600
  • 10W. R. Blevin. Diffraction losses in radiometry and photometry[J]. Metrologia, 1970, 6(2): 39-44

二级参考文献21

  • 1KEY P J,WARD T H.The Establishment of ultraviolet spectral emission scales using synchrotron radiation[J].Metrologia,1978,14(1):17-29.
  • 2KEY P J,PRESTON R C.Vacuum ultraviolet radiation scales: an accurate comparison between plasma blackbody lines and synchrotron Rradiation[J].Appl. Opt.,1977,16(9):2477-2485.
  • 3KEY P J,PRESTON R C.Magnesium fluoride windowed deuterium lamps as radiance transfer standards between 115 nm and 370 nm[J].J. Phys. E. Sci. Instrum.,1986,13:866-870.
  • 4SAUNDERS R D,OTT W R.Spectral irradiance standard for the ultraviolet: the deuterium lamp[J].Appl. Opt.,1977,17(4):593-600.
  • 5KEY P J,LI F T,NETTLETON D H.NPL Report Qu 65 April.1983[Z].
  • 6LEMKE D,LABS D.The Synchrotron radiation of the 6-GeV DESY machine as a fundamental radiometric standard[J].Appl. Opt.,1967,6(6):1043-1048.
  • 7PITZ E.Absolute calibration of light sources in the vacuum ultraviolet by means of the synchrotron radiation of DESY[J].Appl. Opt.,1969,8(2):255-259.
  • 8FISCHER J,KUHNE M,WENDE B.Spectral radiant power measurements of VUV and soft X-ray sources using the electron storage ring BESSY as a radiometric standard source[J].Appl. Opt.,1984,23(23):4252-4259.
  • 9STOCK M,FISCHER J,FRIEDRICH R,et al.Present state of the comparison between radiometric scales based on three primary standards[J].Metrologia,1993,30:439-449.
  • 10ARNOLD D,ULM G.Electron storage ring BESSY as a source of calculable spectral photon flux in the X-ray region[J].Rev. Sci. Instrum.,1992,63(1): 1539-1542.