水、火电机组协调控制在江西电网的实现 被引量:1

Implementation of Coordinating Control between Hydro Units and Thermal Units in Jiangxi Power Grid
下载PDF
导出
摘要 介绍了江西电网水、火电机组协调控制的实现方法,提出了对水、火电机组分类并施以不同控制策略的新思路:让水电机组调节ACE、火电机组跟踪负荷的趋势分量,可以发挥各自的特点,其效果在实用中得到了证明。 The implementation of coordinating control between hydro units and thermal units in Jiangxi power grid is introduced in this paper, a new strategy which hydro units adjust area control error(ACE) and thermal units trace the trend components of load is also presented. The classification takes advantage of each kind of units and its effectiveness is proved by actual application.
出处 《华中电力》 2006年第2期11-14,共4页 Central China Electric Power
关键词 火电机组 协调控制 AGC hydro, thermal units coordinating control AGC