摘要
本文研究了锌对塞曼效应石墨炉原子吸收法测定硒的基体改进作用,用200mg/L的锌加入硒试液后,使灰化温度达到1000℃,灵敏度提高4.5倍。在最佳条件下,特征质量为29.9pg/0.0044A,检测限为5.3μg/L。校正曲线线性范围为0~600μg/L,50μg/L硒标准溶液9次测定的RSD为5.4%。含有200mg/L锌试液中,10mg/L的Ag、Ca、Cd、Cr、Cu、Fe、K、Ni、Mg、Mn和Sn不干扰200μg/L硒的测定,所建立的方法应用于废水中硒的测定,回收率令人满意。
The matrix modification effect of zinc for Zeeman effect graphite furnace atomic absorption spectrotnetric determination of selenium has been studied. The addition of 200mg/L Zn to selenium solution allows a maximum charring temperature of 1000℃ and results in 4.5--fold increase in sensitivity.Under optimum conditions , a characteristic mass of 29. 9pg/0. 0044A and a detection limit of 5.3μg/L are obtained. Linearity of the calibration curve is abserved in the range of 0--600μg/L Se. Nine determinations of a 50μg/L Se standard solunon gives a RSD of 5.4%.For a 200μg/L Se solution containing 200mg/L Zn, 10mg/L of K,Ag,Ca,Cd,Cu,Mg,Mn,Ni,Sn,Fe and Cr causes no significant interference,respectively.The developed method has been applied to the determination of selenium in waste water with satisfactory recoveries being obtained.
出处
《光谱学与光谱分析》
SCIE
EI
CAS
CSCD
北大核心
1996年第3期111-115,共5页
Spectroscopy and Spectral Analysis