介绍了发电机内冷水系统腐蚀的影响因素,以及内冷水处理常用的几种方法,对下花园发电厂现用处理方法所存在的问题进行了分析。通过对微碱性水处理技术的原理分析,结合设备的实际应用情况,证实该处理方法在下花园发电厂的应用达到了预期效果。
Factors causing erosion of generator internal cooling water as well as several commonly-used treatment methods is introduced. The present treatment method used in Xiahuayuan Power Plant and existing problems is analyzed. By analyzing weak alkaline water treatment technology and considering the application of the equipment,it is proved that this technology has achieved satisfactory result in Xiahuayuan Power Plant.