对同一分质供水住宅小区的给水设计秒流量用不同的两种方法进行了计算并做了比较,阐明了分质供水住宅建筑给水设计秒流量计算应以不同给水管道对应的卫生器具给水当量为准,才能得出正确、合理的结果。
Two different methods are introduced to calculate water supply design flow design load in one residential quarters with water supply systems with different quality. Author points out that in order to make calculation more reasonable and correct calculation of water supply design flow design load should take equivalents of sanitary fixtures as standards.
出处
《山西建筑》
2006年第11期176-177,共2页
Shanxi Architecture
关键词
分质供水
住宅建筑
设计秒流量
water supply systems with different quality, residential building, water supply design flow design load