摘要
某厂常减压车间两台L型压缩机试车时管系振动异常激烈。对气流脉动、气柱固有频率和压缩机及管系结构进行全面理论计算和分析后,提出了切实有效的改造措施,管系振动得到了控制。
After gas flow pulse.gas column frequency and structure of the compressor and his pipeline were calculated and analysed. The efficient.practicable methods have been adopted,and vibration of the pipeline have been controlled.
出处
《压缩机技术》
1996年第3期15-18,共4页
Compressor Technology