研究了用钼酸盐和丁基罗丹明B(BRB)比色测定实际样品中的钌。离子缔合物的最大吸收位于570nm,摩尔吸光度ε值为1.01×106L·mol-1·。cm-1.桑德尔灵敏度0.11ngcm-2.遵守比耳定律范围0~1.4μg/25ml,测定极限3.3ng/ml(m=8),标准偏差8.3×10-4~8.7×10-3,相对标准偏差0.8%~3.3%。考察了43种共存离子的容许量。本法已用于某些岩矿和冶金产品中钌的测定。
A new reaction between ruthenium (Ⅲ ) and molyodate and butylrhodamine B(BRB) has been investigated for the colorimetric determination of ruthenium in actual samples. The ion associate complex absorbs at 570nm with a molar absorptivity of 1.01×106 L·mol-1·cm-1 and a Sandell's sensitivity of 0. 11 ng·cm-2. Beer's law is valid at 0 -1. 4 ug/25ml for ruthenium. The detection limit was 3. 3ng/ml (n=8). The standard deviation are 8. 3×10-4-8.7×10--3. The relative standard deviation was in the range of 0. 8%-3.3%. Tolerance limits for 43 foreign ions were tested. Large quantities of other common metals were tolerated. The method is feasible for deterndnation of ruthenium in some ores and metallurgical products.
出处
《黄金》
CAS
北大核心
1996年第4期48-51,共4页
Gold