摘要 研究了碳纤维水泥基复合材料在干燥和水饱和两种状态下的导电性能。实验结果表明:当碳纤维掺量低于渗流阈值时,材料是以离子和隧道效应导电,干燥状态下导电率显著降低;当碳纤维掺量大于渗流阈值时,材料以碳纤维网络导电,干燥状态下导电率反而增加。分析表明,干燥状态下碳纤维含量低于阈值时导电率降低是由于离子活度降低之故、而碳纤维掺量高于阈值时导电率的增加是由于纤维间水膜的消失而相互搭接形成网络导电之故。
出处 《混凝土与水泥制品》 2006年第3期43-45,共3页 China Concrete and Cement Products
基金 国家自然科学基金资助项目(50272061)
  • 相关文献

参考文献7

二级参考文献19

  • 1毛起,赵斌元,沈大荣,李卓球.水泥基碳纤维复合材料压敏性的研究[J].复合材料学报,1996,13(4):8-11. 被引量:74
  • 2[1]Bazant Z P, Wittmann F H. Creep and Shrinkage in Concrete Structures. New York: Wiley, 1980.
  • 3[2]Shimomura T, Maekawa K. Analysis of the Drying Shrinkage Behaviour of Concrete Using a Micromechanical Model Based on the Microscopre Structure of Concrete. Magazine of Concrete Research, 1997, 49(181): 303~322
  • 4[3]Grzybowski M, Shah S P. Model to Predict Cracking in Fiber Reinforced Concrete Due to Restrained Shrinkage.Magazine of Concrete Research, 1989, 41 (148):125~ 135
  • 5[4]Kim J K, Lee C S. Prediction of Differential Drying Shrinkage in Concrete. Cement and Concrete Research, 1998, 28(7): 985~994
  • 6Sherif Yehia, Christopher Y Tuan, David Ferdon, et al. Conductive Concrete Overlay/or Bridge Deck Deicing: Mixture Proportioning, Optimization, and Properties. ACI Materials Journal[ J ]. 2000, (2) : 172 - 181.
  • 7Sihai Wen, D. D. L. Chung. Carbon Fiber-Reinforced Cement as a thermistor[J ]. Cement and Concrete Research, 1999, 29(6) :961 - 965.
  • 8唐祖全.碳纤维机敏混凝土路面结构融雪化冰性能研究[C].,2002.41-45.
  • 9WEN S, CHUNG D D L. Damage monitoring of cement paste by electrical resistance measurement[J]. Cem Concr Res,2000,30(12):1979-1982.