期刊文献+

板式地板辐射供暖系统传热性能模拟研究 被引量:2

Simulative Research on Heat Transfer Performance of Panel Radiant Floor Heating System
下载PDF
导出
摘要 建立了板式地板辐射供暖的二维稳态传热模型。采用有限元分析软件ANSYS,分析了地板表面温度分布、传热计算单元内部温度分布、地板表面热流密度的影响因素及地板表面平均温度的影响因素,在考虑地板向下传热时对模拟计算结果进行了修正。供、回水平均温度是影响地板表面热流密度和平均温度的主要因素。当室内温度为20℃时,在维持适宜的地板表面平均温度范围24~28℃的前提下,供、回水平均温度的变化范围为27~34℃,考虑地板向下传热后,应控制在30~35℃。考虑地板向下传热后,应将模拟计算结果乘以一个不小于0.9的修正系数。 A model for two-dimensional steady-state heat transfer of panel radiant floor heating system is established. The floor surface temperature distribution, the interior temperature distribution of heat transfer calculation unit and the influencing factors of floor surface heat flow density and average floor surface temperature are analyzed with finite element analysis software ANSYS. While considering the downward heat transfer of floor, the simulative calculation result is corrected. The average supply and return water temperatures are main factors affecting floor surface heat flow density and average floor surface temperature. When the indoor temperature is 20 ℃, going on the premise of maintaining the appropriate average floor surface temperature between 24 ℃ and 28 ℃, the variation range of average supply and return water temperatures is between 27 ℃ and 34 ℃. Taking account of the downward heat transfer of floor, the variation range of average supply and return water temperatures should be controlled between 30 ℃ and 35 ℃, and the simulative calculation result should be multiplied by a correction coefficient of not less than 0.9.
出处 《煤气与热力》 2006年第7期70-73,共4页 Gas & Heat
关键词 板式地板辐射供暖 模拟计算 热流密度 panel radiant floor heating system simulative calculation heat flow density
  • 相关文献

参考文献5

  • 1王海霞.板式地板辐射供暖传热性能的研究(硕士学位论文)[D].天津:天津大学,2004.
  • 2Kilkis I B, Eltez M, Sager S S. A simplified model for the design of radiant in-slab heating panels [ J ]. ASHEAE Transactions, 1995, 101 ( 1 ) : 210 - 216.
  • 3Kilkis I B, Sapci M. Computer-aided design of radiant subfloor heating systems [ J ]. ASHRAE Transactions,1995, 101 ( 1 ) : 1214 - 1220.
  • 4JGJ142—2004,地面辐射供暖技术规程[S].
  • 5Kilkis I B. Development of a complete design software for hydronic floor heating of buildings [ J ]. ASHRAE Transactions, 1995, 101 (1) : 1201 - 1209.

共引文献2

同被引文献22

  • 1邱林,王文海,程韧.干式结构地板采暖运行模式的实验研究[J].节能技术,2004,22(5):7-9. 被引量:5
  • 2邱林,刘肇生,裴立德,王文海.采用预应力空心楼板与干式地面结构的地板采暖的可行性研究[J].建筑科学,2005,21(3):44-47. 被引量:5
  • 3Fontana L. Thermal performance of radiant heating floors in furnished enclosed spaces [ J ]. Applied Thermal Engineering, 2011,31 : 1547-1555.
  • 4Lu Shikui, Zhang Xiaosong. Thermal comfort assess- ment and energy consumption analysis of ground-source heat pump system combined with radiant heating/cool- ing [ J ]. Journal of Southeast University,2012,28 ( 1 ) : 52-57.
  • 5Ehab Foda, Kai Siren. Design strategy for maximizing the energy-efficiency of a localized floor-heating system using a thermal manikin with human thermoregulatory control [ J ]. Energy and Buildings, 2012,51 : 111-121.
  • 6Birol Kilkis. Exergy metrication of radiant panel heat- ing and cooling with heat pumps [ J]. Energy Conver- sion and Management,2012,63: 215-224.
  • 7Dongliang Zhang, Ning Cai, Zijie Wang. Experimental and Numerical Analysis of Lightweight Radiant Floor Heating System [ J ]. Energy and Buildings, 2013,61 : 260-266.
  • 8Gebhart B. Surface temperature calculations in radiant surroundings of arbitrary complexity--for gray, diffuse radiation [ J ]. International Journal of Heat and Mass Transfer, 1961,3 ( 4 ) : 341-346.
  • 9Yoshihito Kurazumi, Tadahiro Tsuchikawa, Jin Ishii, et al. Radiative and convective heat transfer coefficients of the human body in natural convection [ J ]. Building and Environment,2008,43:2142-2153.
  • 10Buratti C, Ricciardi P, Vergoni M. HVAC systems tes- ting and cheek: A simplified model to predict thermal comfort conditions in moderate environments [ J ]. Ap- plied Energy,2013,104 : 117-127.