期刊文献+

圆锥角膜行非机械性全层角膜移植术后拆除连续缝线导致的角膜功能和屈光度的改变情况 被引量:1

Changes in corneal power and refraction due to sequential suture removal following nonmechanical penetrating keratoplasty in eyes with keratoconus
下载PDF
导出
摘要 Purpose: To assess the changes in corneal power and refraction due to sequential suture removal after penetrating keratoplasty (PK). DESIGN: Retrospective consecutive case series. METHODS: SETTING: Clinical practice. STUDY POPULATION: We studied 67 phakic keratoconus eyes (central excimer laser trephination, primary keratoplasty, graft/recipient diameter 8.1/8.0 mm; double running suture) in this longitudinal study. MAIN OUTCOME MEASURES: Zeiss keratometry (equivalent power (KEQ), astigmatism (KAST)), corneal topography (equi-valent power (TEQ), astigmatism (TAST)) and subjective refractometry (spherical equivalent (SEQ), refractive cylinder (RAST)) were assessed with sutures in place (interval 1), with one suture out (interval 2), and with all sutures out (interval 3). OBSERVATION PROCEDURE: Corneal power and refraction was decomposed into vector components and the changes were derived between time stages. RESULTS: The mean follow-up period was 3.9 ±1.7 years. At interval 1, the axes of KAST/TAST/RAST were almost randomly distributed. At interval 2, the with/against the rule component of KAST/TAST/RAST decreased slightly and the oblique component increased significantly, so that the axes tended to have a preferred oblique direction. At interval 3, the with/against the rule component of KAST/TAST/RAST increased slightly and the oblique component decreased significantly, so that the with/against the rule component exceeded the oblique component by approximately 23%/28%/25%. Median KEQ/ TEQ/SEQ changed by 0.64/0.62/-1.11 diopters (interval 1 to interval 2) and by -0.85/-0.90/1.56 diopters (interval 2 to interval 3). CONCLUSIONS: As a result of removal of the first running suture, corneal astigmatismas well as the refractive cylinder tend to oblique axes. As a result of removal of the second running suture, the final corneal astigmatism and refractive cylinder tend to orientation axes with/against the rule. Purpose: To assess the changes in corneal power and refraction due to sequential suture removal after penetrating keratoplasty (PK) . DESIGN: Retrospective consecutive case series. METHODS: SETTING: Clinical practice. STUDY POPULATION: We studied 67 phakic keratoconus eyes (central excimer laser trephination, primary kerato- plasty, graft/recipient diameter 8.1/8.0 ram; double running suture) in this longitudinal study. MAIN OUT- COME MEASURES: Zeiss keratometry (equivalent power (KEQ), astigmatism (KAST)), corneal topography (equivalent power (TEQ), astigmatism (TAST)) and subjective refractometry (spherical equivalent (SEQ), refractive cylinder (RAST)) were assessed with sutures in place (interval 1), with one suture out (interval 2), and With all sutures out (interval 3). OBSERVATION PROCEDURE: Corneal power and refraction was decomposed into vector components and the changes were derived between time stages. RESULTS: The mean followup period was 3.9±1.7 years. At interval 1, the axes of KAST/TAST/RAST were almost randomly distributed. At interval 2, the with/against the rule component of KAST/TAST/RAST decreased slightly and the oblique component increased significantly, so that the axes tended to have a preferred oblique direction. At interval 3 .
出处 《世界核心医学期刊文摘(眼科学分册)》 2006年第5期10-11,共2页 Digest of the World Core Medical Journals:Ophthalmology
  • 相关文献

同被引文献4

引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部