期刊文献+

燃气轮机发电机组静止变频启动装置研究 被引量:15

Study on the static frequency converter for gas turbine generator sets
下载PDF
导出
摘要 近年来我国进口了数十套燃燃气轮机发电机组,它们利用发电机及相应的变频启动装置启动。而变频启动装置由于采用可控硅(SCR)整流再逆变原理,其输出电压电流波形差,致使输出效率低、力矩小;另外,谐波分量大,不能满足国家相关标准要求。为此,利用绝缘栅双极型功率晶体管(IGBT)器件替代可控硅元件设计了一种新技术装置。结果表明,后者输出的谐波非常理想,性能指标远远超过前者,可全面满足国家相关标准。 In recent years, several dozen Gas Turbine (GT)generator sets have been imported into China. The generator of the GT generator set is applied as the starter which is controlled by the Static Frequency Converter(SFC). Unfortunately, the SFC provides output voltage and current wave forms of a poor quality and consequently low torque and efficiency due to using Silicon Control Rectifier (SCR) for the converter design, which cannot meet the requirements of the relevant state standard. To solve this problem a new converter is designed using IGBT instead of SCR. Test results show that with the new converter using IGBT perfect output waves can be obtained. Its performance is better than that of the converter with SFC and can fully meet the relevant state standard.
出处 《能源研究与信息》 2006年第2期98-102,共5页 Energy Research and Information
关键词 燃气轮机 可控硅 绝缘栅双极型功率晶体管 变频启动装置 gas turbine silicon control rectifier insulator gate bipolar transistor static frequency converter
  • 相关文献

参考文献3

  • 1CHIANG Juag-chen,WU Chi-jui.Mitigation of harmonic disturbance at pumped storage power station with static frequency converter[J].IEEE Transactions on Energy Conversion,1997,12(3):232-240.
  • 2MAGSAYSAY Greg,SCHUETTE Thomas,FOSTIAK Russ.J.Use of a static frequency converter for rapid load response in pumped-storage plants[J].IEEE Transactions on Energy Conversion,1995,10(4):694-699.
  • 3LIU Tian-hua,LIN Chih-ying,YANG Jin-shyr,CHANG Wen-yao.Modeling and harmonics elimination for a static frequency converter driving a 300 MVA synchronous machine[R].Power Research Institute,National Taiwan Institute of Technology,1996.