摘要
从干井式温度校验器的独特性着手,通过分析当前参照的测试规范在校准干井式温度校验器时存在的不适用以及干井炉校准时应注意的一些问题,对其校准方法进行了研究和探讨,并初步总结出了一套实用的干井炉校准方法。
The calibration method of the dry-well calibrator is studied in this paper, from its particularity by explaining the inapplicability of existing regulation and some factors of effecting the temperature field of the dry-well calibrator. And then a practical calibration method for the dry-well calibrator has been sumed up.
出处
《计测技术》
2006年第3期41-42,58,共3页
Metrology & Measurement Technology