期刊文献+

髋关节置换术后早期异常X线表现分析 被引量:1

Analysis of Early Abnormal X-ray Features after Hip Joint Replacement
下载PDF
导出
摘要 目的:探讨髋关节置换术后早期异常X线表现、成因及与临床的关系。方法:回顾性分析102例髋关节置换术后患者的术后CR图像及病例资料。结果:102例中共15例髋部有异常X线表现:假体髋臼结构异常并发脱位2例、并发劈裂骨折2例、大转子位置偏高4例、碎骨片及异位骨化钙化、残留7例、假体钢丝断裂错位1例。髋关节置换术后早期异常X线表现可分术后并发症及关节结构异常两大类。结论:髋关节置换术后早期异常X线表现不同,其成因及与临床的关系也不同,但互有联系,必须正确认识。 Objective: To study the early abnormal X-ray features after hip joint replacement, the causes and their clinical relationship. Methods:Retrospectively analyzed the post-surgical CR features and their clinical materials of 102 patients after hip joint replacement. Results: Of the 102 patients, 15 patients had abnormal X-ray features: prosthesis-acetabulum str.uctural abnormalities associated with hip joint dislocation (n= 2) , associated with fissured fracture (n=2), upward displacement of greater trochanter (n= 4), residue bone fragment and ectopic ossification or calcification (n= 7), mal-position of prosthesis due to broken steel wire (n= 1). The causes of early abnormal X-ray features after hip joint replacement could be divided into two groups, including post-surgical complication and abnormalities due to arthrosis. Conclusion:There were various early abnormal X-ray features after hip joint replacement, which had different clinical causes, however, to recognize these issues is essential.
出处 《放射学实践》 2006年第7期716-718,共3页 Radiologic Practice
关键词 放射摄影术 关节成形术 置换 手术后并发症 Radiology Arthroplasty, replacement, hip, Postoperative complications
  • 相关文献

参考文献6

二级参考文献16

  • 1[1]Dorr LD, Wan Z. Causes of and treatment protocol for instability of total hip replacement. Clin Orthop, 1998,335:144-151.
  • 2[2]Turner RS. Postoperative total hip prosthetic femoral head dislocations. Incidence, etiologic factors, and management. Clin Orthop, 1994,301:196-204.
  • 3[3]Woo RY,Morrey BF. Dislocations after total hip arthroplasty. J Bone Joint Surg(Am), 1982,64 (9):1295-1306.
  • 4[4]Pierchon F,Pasquier G, Cotton A, et al. Causes of dislocation of total hip arthoplasty. CT study of component alignment. J Bone Joint Surg (Br) ,1994,76(1):45-48.
  • 5屈辉,中华放射学杂志,1995年,30卷,672页
  • 6Barrack RL, Mulroy RD, Harris WH. Improved cementing techniques and femoral component loosening in young patients with hip arthroplasty:a 12-year radiographic review. J Bone Joint Surg[Br],1992,74:385-389.
  • 7Callaghan JJ, Forest EE, Olejniczak JP,et al. Charnley total hip arthroplasty in patients less than fifty years old:a twenty to twenty-five-year follow-up note. J Bone Joint Surg,1998,80:704-714.
  • 8Weissman BN. Imaging of total hip replacement. Radiology, 1997, 202: 611-623.
  • 9Beckenbaugh RD, Ilstrup DM. Total hip arthroplasty. J Bone Joint Surg[Am],1978,60:306-313.
  • 10Spector M, Shortkroff S, Hsu HP, et al. Tissue changes around loose prostheses: a canine model to investigate the effects of anti-inflammatory agent. Clin Orthop,1990,261:140-152.

共引文献45

同被引文献49

引证文献1

二级引证文献6

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部