摘要 本工作研制建立1套气体放射性活度绝对测量装置———内充气正比计数管系统。对该系统的坪特性、本底、死时间、端效应和壁效应等性能进行了测试。在此基础上,采用该系统对放射性气体87Kr的放射性活度浓度进行了绝对测量,测得值为40.64(1±0.9%)Bq/mL。 A internal gas proportional counting system for absolute measurement of gas radioactivity was established. The performances of the system, such as plateaus, background, deadtime, end effect and wall effect were well tested. Then the activity concentration of 87^ Kr was measured absolutely to be 40.64 (1±0.9 %) Bq/mL by this equipment.
出处 《原子能科学技术》 EI CAS CSCD 北大核心 2006年第4期443-446,共4页 Atomic Energy Science and Technology
关键词 内充气正比计数管 绝对测量 放射性活度浓度 87^Kr internal gas proportional counter absolute measurement activity concentration 87^Kr
  • 相关文献

参考文献5

  • 1翁守清.4π 内气体源的绝对测量[J].核电子学与探测技术,1998,18(1):33-36. 被引量:6
  • 2MANN W B,MEDLOCK R W,YURA O.A re-calibration of the national bureau of standards tritiated water standards by gas counting[J].International Journal of Applied Radiation and Isotopes,1964,15:351-361.
  • 3MERRITT W F,HAWKINGS R C.The absolute assay of sulfur-35 by internal gas counting[J].Analytical Chemistry,1960,32(3):308-310.
  • 4MAKEPEACE J L,CLARK F E,PICOLO J L.Intercomparison of internal proportional gas counting of 85Kr and 3H[J].Nuclear Instruments and Methods in Physics Research,1994,A339:343-348.
  • 5JAGDISH K T.Nuclear wallet cards[M].6th ed.New York:Brookhaven National Laboratory,2000:17.

共引文献5

同被引文献33

  • 1张利兴.禁核试核查中放射性惰性气体的监测[J].核技术,2004,27(10):770-777. 被引量:24
  • 2周友朴,王斌,阙毅,陈宝流.放射性气体活度绝对测量[J].原子能科学技术,1994,28(3):194-199. 被引量:8
  • 3Mann W B, Medlock R W, Yura O. A recalibration of the national bureau of standards tritiated water standards by gas counting[J]. International Journal of Applied Radiation and Isotopes, 1964, 15. 351-361.
  • 4Merritt W F, Hawkings R C. The absolute assay of sulfur-35 by internal gas counting[J]. Analytical Chemistry, 1960, 32(3) :308-310.
  • 5Makepeace, J. L. Clark, F. E. Picolo, J. L. Coursol. 1994. Nucl. Instrum. Methods 339,343-348.
  • 6Paul R. J. Saey. Ultra-Low-Level Measurements of Argon, Krypton and Radioxenon for Treaty Verification Purposes[J]. ESARDA BULLETIN, 36 : 42-56.
  • 7Heusser, G. , Low-radioactivity background technique[J-]. Ann. Rev. Nucl. Part. Sci., 1995,45. 543-590.
  • 8向永春,等.能谱法测量^37Ar的实验研究[R].中国工程物理研究院国防科技报告,2006.
  • 9Gazfinkel SB, MannWB, Schirna FJ, etal. Present Status in The Field of Internal Gas Counting [J]. Nulcl. Instr. and Meth, 1973, 112:59.
  • 10D. Stanga, J. L. Picolob, N. Coursolb, K. Mitevc, I. Moreau. Analytical calculations of counting losses in internal gas proportional counting[J]. Applied Radiation and Isotopes, 2002,56 : 231-236.

引证文献7

二级引证文献8

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部