期刊文献+

国产C-L短柱侧倾碟瓣主动脉瓣置换术后中期血流动力学的评价 被引量:3

Midterm Haemodynamic Assessment of the Home-made C-L Pugestrut Tilting Disc Mechanical Valve in Aortic Valve Replacement
下载PDF
导出
摘要 目的观察国产C-L短柱侧倾碟瓣主动脉瓣置换术后中期血流动力学的表现,并评价其功能。方法选择20例单纯主动脉瓣置换术后>5年的患者分为2组,C-L短柱侧倾碟瓣组:采用C-L短柱侧倾碟瓣(21mm)行主动脉瓣置换术;M edtron ic-H a ll组:采用M edtron ic-H a ll侧倾碟瓣(21mm)行主动脉瓣置换术,每组10例。比较两组静息状态下的最大跨瓣压差(ΔP)、平均跨瓣压差(ΔPm)和瓣膜有效开口面积(EOA)。结果在静息状态下,C-L短柱侧倾碟瓣组和M edtron ic-H a ll组的ΔP分别为11.63±3.23mmHg(1kPa=7.5mmHg)和9.78±3.35mmHg,ΔPm分别为6.25±2.32mmHg和5.85±2.32mmHg,EOA分别为1.07±0.17cm2和1.25±0.27 cm2,两组比较差异无统计学意义(P>0.05)。结论主动脉瓣置换术后中期血流动力学检测结果显示,C-L短柱侧倾碟瓣与M edtron ic-H a ll侧倾碟瓣的血流动力学结果相似,其功能良好,是一个可靠的心脏瓣膜。 Objective To observe the midterm haemodynamic manifestation of the home made C-L pugestrut tilting disc mechanical valve in aortic valve replacement, and to evaluate its function. Methods Twenty patients underwent aortic valve replacement over 5 years were collected and divided into two groups, the C-L pugestrut group (n=10):aortic valve was replaced by home-made C-L pugestrut tilting disc mechanical valve(21mm); Medtronic-Hall group (n=10):aortic valve was replaced by Medtronic-Hall mechanical valve (21mm). The peak transprosthetic gradients (△P), mean transprosthetic gradients (△Pm)and effective orifice area(EOA) at rest were compared between two groups. Results At rest, △P of the C-L pugestrut group and Medtronic-Hall group were 11.63±3.23mmHg vs. 9. 78±3. 35mmHg; △Pm of the C-L pugestrut group and Medtronic-Hall group were 6. 25±2. 32 mmHg vs. 5.85±2.32mmHg: EOA of the C-L pugestrut group and Medtronic-Hall group were 1.07±0.17 cm^2 vs. 1.25±0.27 cm^2. There was no statistically significance in △P, △Pm and EOA between two groups(P〉0.05). Conclusions The midterm haemodynamic results of the home-made C-L pugestrut tilting disc mechanical valve show that it has comparable haemodynamic results to those of Medtronic-Hall mechanical valve ,and it has well-done function. The home-made C-L pugestrut valve is one of the reliable mechanical heart valves.
出处 《中国胸心血管外科临床杂志》 CAS 2006年第4期218-220,共3页 Chinese Journal of Clinical Thoracic and Cardiovascular Surgery
关键词 心脏瓣膜疾病 血流动力学 最大跨瓣压差 平均跨瓣压差 瓣膜有效开口面积 Heart valve disease Hemodynamics Peak transprosthetic gradient Mean transprostheticgradient Effective orifice area
  • 相关文献

参考文献14

  • 1邹良建,张宝仁,朱家麟,朱泉芳.C-L短柱瓣体外流体动力学评价[J].第二军医大学学报,1999,20(12):1006-1008. 被引量:9
  • 2王志农,朱家麟,张宝仁,郝家骅,李文放.应用C-L短柱瓣行瓣膜替换术后早期血液动力学的变化[J].第二军医大学学报,1997,18(S1):10-14. 被引量:9
  • 3Holen J, Aaslid R,Landmark K, et al. Determination of pressure gradient in mitral stenosis with a non-invasive ultrasound Doppler technique. Acta Med Scand,1976,199(6):455-460.
  • 4朱家麟,张宝仁,郝家骅,于伟勇,徐志云,梅举,邹良建,孙道华,王志农,朱泉芳.新型国产C-L短柱侧倾碟瓣的临床应用[J].第二军医大学学报,1997,18(S1):7-9. 被引量:8
  • 5孟旭,刘岩,陈宝田,董然.四种人工机械瓣膜的临床对比研究[J].中国胸心血管外科临床杂志,2001,8(4):269-271. 被引量:4
  • 6高峰,胡盛寿,唐跃,孟亮,袁卫明,周燕文.国产双叶机械瓣长期存活动物模型的建立[J].中国胸心血管外科临床杂志,2003,10(2):149-150. 被引量:3
  • 7Anttila V, Heikkinen J, Biancari F, et al. A retrospective comparative study of aortic valve replacement with St. Jude medical and medtronic-hall prostheses: a 20-year follow-up study. Scand Cardiovasc J,2002,36(1):53-59.
  • 8Remadi JP, Baron O, Roussel C, et al. Isolated mitral valve replacement with St. Jude medical prosthesis:long-term results: a follow-up of 19 years. Circulation, 2001, 103 (11):1542-1545.
  • 9Lund O, Nielsen SL, Arildsen H, et al. Standard aortic St. Jude valve at 18 years: performance profile and determinants of outcome. Ann Thorac Surg, 2000,69(5):1459-1465.
  • 10Leung DY, Wong J, Rodriguez L, et al. Application of color Doppler flow mapping to calculate orifice area of St. Jude mitral valve. Circulation, 1998,98(12):1205-1211.

二级参考文献9

  • 1朱家麟,张宝仁,郝家骅,于伟勇,徐志云,梅举,邹良建,孙道华,王志农,朱泉芳.新型国产C-L短柱侧倾碟瓣的临床应用[J].第二军医大学学报,1997,18(S1):7-9. 被引量:8
  • 2王志农,朱家麟,张宝仁,郝家骅,李文放.应用C-L短柱瓣行瓣膜替换术后早期血液动力学的变化[J].第二军医大学学报,1997,18(S1):10-14. 被引量:9
  • 3王志农,朱家麟,张宝仁,郝家骅,陈如坤.心脏瓣膜替换术后氧的供需关系变化[J].中国循环杂志,1995,10(5):273-277. 被引量:6
  • 4[1]Butchart EG,Lewis PA, Bethel JA, et al. Adjusting anticoagulation to prosthesis thrombogenicity and patient risk factors. Recommendations for the Medtronic-Hall valve.Circulation,1991,84(Suppl 5):61-69.
  • 5[2]Krian A,Matloff J M,Nicoloff D M.Advancing the technology of bileaflet mechanical heart valves. New York, Berlin, London: Springer,1998.53-73.
  • 6[3]Casselman F,Herijgers P,Meyns B.The Bicarbon heart valve prosthesis:short-term result.J Heart Valve Dis,1997,6(4):410-415.
  • 7Bianco RW.St Cyr JA, Schneider JR, et al. Canine model for long-term evaluation of prosthetic mitral valves. J Surg Res,1986, 41(2):134-140.
  • 8Ali ML, Kumar SP, Bjornstad K, et al. The sheep as an animal model for heart valve research. Cardiovasc Surg, 1996,4(4):543-549.
  • 9邹良建,上海生物医学工程,1993年,43卷,3期,6页

共引文献16

同被引文献41

引证文献3

二级引证文献14

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部