摘要
华电蒲城发电有限责任公司2台罗马尼亚330MW机组在起动过程中出现了中压缸温度异常变化情况,分析了缸温异常变化带来的危害,总结了引起汽缸温度异常变化的原因,提出了相应的防范措施。
For two 330 MW units made by Romania and installed in Huadian Pucheng Power Generating Co Ltd, unusual temperature variation concerning medium-pressure cylinder has occurred in start-up process of said units. The harmfulness resulting from unusual variation of cylinder temperature has been analysed, and the causes leading to unusual variation of cylinder temperature being summarized, and then corresponding preventive measures being put forward.
出处
《热力发电》
CAS
北大核心
2006年第8期33-35,共3页
Thermal Power Generation
关键词
330
MW机组
中压缸起动
上下缸温差
缸温异常
热应力
蒲城电厂
330 MW unit
start-up of the mediumpressure cylinder
temperature difference
unusual cylinder temperature
thermal stress
Pucheng Power Plant