摘要
比较和分析了冷凝热回收冷水机组和只供冷冷水机组的构造特点和系统运行工况特征,提出了冷凝热回收系统的设计原则,并论及了该系统的经济效益。
Compares the water chiller with condenser heat recovery and the one without in their structure and operation, puts forward three points based on the principle in design of the former i. e. to ensure the hishest year-round operation efficiency of the unit, and evaluates its economics by a simple example.
出处
《暖通空调》
北大核心
1996年第6期31-35,共5页
Heating Ventilating & Air Conditioning
关键词
热回收
系统
冷凝器
效率
空调
heat recovery
system
condenser
operating point
efficiency