介绍了除盐水站再生系统流程,对除盐水站存在的酸、碱腐蚀问题进行了分析。从合理设计、选材、消除应力、添加缓蚀剂、加强运行及维护管理等方面提出了一系列避免或减缓腐蚀危害的防护措施,主要从设计角度对除盐水站的安全生产及环境保护等问题进行了讨论。
The process flow of regeneration system of desalted water station is described and the corrosion problems are analyzed. Corrosion protection or mitigation measures are suggested in respect of design, material selection, stress release, application of corrosion inhibitor, strengthened unit operation and maintenance management etc. The safety operation and environmental protection of the station are also discussed in respect of design.
出处
《炼油技术与工程》
CAS
北大核心
2006年第8期59-62,共4页
Petroleum Refinery Engineering
关键词
除盐水站
腐蚀
防护
设计
选材
应力腐蚀开裂
缓蚀剂
desalted water station, corrosion, protection, design, material selection, stress corrosion cracking, corrosion inhibitor